I. Core Advantages of the Instrument

  1. Dual-channel power supply design: Compared with the traditional single-channel power supply mode, the dual-channel power supply significantly enhances the energy of the excitation light source, effectively improves the instrument detection sensitivity, and ensures accurate capture of trace elements.
  2. Integrated multi-functional reaction module: It highly integrates key functions such as hydrogenation reaction, gas-liquid separation and waste liquid discharge. The pressure self-balanced waste liquid discharge system does not require additional pump assistance, which greatly simplifies the instrument structure, reduces the probability of failure, and ensures stable and controllable reaction process.
  3. 3D orbital adjustment mechanism: Replacing the traditional two-dimensional adjustment mode, it supports three-dimensional adjustment (up & down, left & right, front & back) of the atomizer, with more convenient operation and more accurate positioning. It can quickly optimize the excitation effect and further improve the instrument sensitivity.

II. Basic Functional Configuration

  • Supports single-channel detection and dual-channel simultaneous detection modes to meet the needs of different detection scenarios.
  • Equipped with the functions of establishing single-point, two-point and multi-point standard curves, as well as correcting single-point and two-point standard curves to ensure the accuracy of detection data.
  • Covers comprehensive injection mode control including continuous flow injection and traditional injection, suitable for various sample types.
  • Real-time observation of the whole test process, supporting online adjustment of the three-dimensional parameters of the atomizer for timely optimization of test conditions.
  • Optional fast intelligent automatic sampler to improve detection efficiency and reduce manual operation errors.
  • Equipped with a user-friendly software interface that can recommend the optimal instrument test conditions; supports graphical display, playback, statistics and query of test data, as well as page saving, output, backup and printing of various graphics and data; the suspended measurement window design increases the number of displayable information such as fluorescence intensity and blank value.
  • Built-in instrument self-test function and gas cut-off early warning protection system to fully guarantee the stable operation of the instrument and the safety of operators.
  • Optional harmful element capture device in the detection tail gas, complying with environmental protection requirements.
  • Seamless connection with liquid phase and online digestion modules to realize speciation analysis of As, Hg, Se and other elements.

III. Technical Specifications (International Standard)

Test Elements As, Sb, Bi, Pb, Sn, Te, Se Zn Ge Cd, Hg
Detection Limit (DL) < 0.01 ng/mL < 1.0 ng/mL < 0.05 ng/mL < 0.001 ng/mL
Repeatability (RSD) 0.6%
Linear Range More than three orders of magnitude
Inter-channel Interference < 0.5%
Test Time 30s / 3 sets of data

 

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

The instrument requires connection to a gas supply and proper ventilation to manage toxic hydride vapors from hydrogenation reactions. It features a gas cut-off early warning system and optional harmful element capture device to ensure operator safety.

  • Reaction Module Constraint: The integrated multi-functional reaction module operates with a pressure self-balanced waste liquid discharge system that does not require additional pump assistance.
  • Power Supply Requirement: The dual-channel power supply design enhances excitation light source energy and requires a stable electrical connection.
  • Atomizer Adjustment Constraint: The 3D orbital adjustment mechanism allows precise positioning of the atomizer in three dimensions for optimal excitation.
  • Detection Mode Compatibility: The instrument supports both single-channel and dual-channel simultaneous detection modes for various test scenarios.
  • Environmental Protection Requirement: An optional harmful element capture device can be installed to treat detection tail gas in compliance with environmental regulations.

Initialize the instrument by running the built-in self-test and verifying gas supply connections. Proceed to set up detection parameters and perform calibration before sample analysis.

Required Equipment: Atomfair-ASF-739 Portable Atomic Fluorescence Spectrometer, Instrument software interface

  1. Run Self-Test
    Run the instrument self-test function to verify system integrity and gas cut-off warning system.
  2. Configure Detection Mode
    Configure the detection mode and standard curve type via the software interface.
  3. Inject Sample
    Inject the sample using the continuous flow or traditional injection mode.
  4. Monitor and Adjust
    Monitor the fluorescence intensity and blank value in real time and adjust atomizer parameters if needed.
  5. Discharge Waste
    Discharge waste using the pressure self-balanced system and clean the reaction module after completion.

What are the detection limits for arsenic and mercury on the Atomfair ASF-739 portable atomic fluorescence spectrometer?

For arsenic (As) and elements in its group (Sb, Bi, Pb, Sn, Te, Se), the detection limit is <0.01 ng/mL. For mercury (Hg) and cadmium (Cd), the detection limit is <0.001 ng/mL. These specifications are explicitly listed in the instrument's technical data sheet.

Can the Atomfair ASF-739 be used for speciation analysis of elements such as arsenic and mercury?

Yes, the ASF-739 supports speciation analysis of As, Hg, Se, and other elements through its seamless connection with liquid phase and online digestion modules. This capability is explicitly stated in the instrument's functional configuration, enabling determination of different chemical forms of these elements.

What built-in safety and infrastructure features does the Atomfair ASF-739 include?

The instrument includes a gas cut-off early warning protection system to ensure operator safety and stable operation, and offers an optional harmful element capture device for detecting tail gas to comply with environmental requirements. Additionally, its dual-channel power supply design enhances excitation source energy for improved sensitivity without additional infrastructure demands.

The Atomfair-ASF-739 Portable Atomic Fluorescence Spectrometer offers dual-channel power supply for enhanced sensitivity and an integrated reaction module for simplified operation, but requires careful handling of its advanced adjustment mechanisms and optional accessories for full capability.

Positive

  • Dual-channel power supply enhancement: The dual-channel power supply design significantly enhances the energy of the excitation light source, effectively improving instrument detection sensitivity for trace elements.
  • Integrated reaction module simplifies structure: The integrated multi-functional reaction module combines hydrogenation, gas-liquid separation, and waste liquid discharge with a pressure self-balanced system, eliminating the need for additional pumps and reducing failure probability.

Trade-offs

  • Requires trained operator for adjustments: The 3D orbital adjustment mechanism and dual-channel modes require operator expertise to optimize excitation conditions and ensure accurate measurements.
  • Optional accessories add cost and complexity: Full functionality may require optional accessories such as the fast intelligent autosampler and harmful element capture device, increasing initial investment and operational complexity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).