PFSA Electrolyzer Membrane 50-175μm ≥140mS/cm ATOMFAIR®

Price range: $430.00 through $600.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research grade PFSA electrolyzer membrane, 50-175μm thick with ≥140 mS/cm proton conductivity for PEM water electrolysis stacks. Order now.

Brands:

PERFLUOROSULFONIC ACID ELECTROLYZER MEMBRANES

RESEARCH GRADE MATERIAL

Product Overview

This premium series of functional ion-exchange resins represents an advanced 50 μm to 175 μm electrolyzer substrate array fabricated into a durable layered perfluorosulfonic acid membrane structure. Specially optimized to increase water electrolysis hydrogen production efficiency, these robust polymer electrolyte sheets deliver excellent thermal stability and reliable mechanical parameters under harsh structural strain. Resistant to intense caustic agents, heavy acids, and severe oxidizers, this versatile membrane family provides exceptional proton conductivity retention and controlled swelling margins for long-term industrial stack sealing operations.

Technical Specifications

PARAMETER ELE-H175 ELE-H120 ELE-H080 ELE-H050
Thickness (μm) 175 ± 10 120 ± 10 80 ± 4 50 ± 3
Tensile Strength
(TD/MD) (MPa)
≥ 25 / 25 ≥ 28 / 28 ≥ 30 / 30 ≥ 30 / 30
Elongation at Break
(TD/MD) (%)
≥ 200 / 200 ≥ 200 / 200 ≥ 250 / 250 ≥ 250 / 250
Young’s Modulus
(TD/MD) (MPa)
≥ 180 / 180 ≥ 200 / 200 ≥ 200 / 200 ≥ 200 / 200
Dimensional Change
(TD / MD / Thickness) (%)
≤ 25 / 25 / 25 ≤ 25 / 25 / 25 ≤ 15 / 15 / 45 ≤ 15 / 15 / 40
Proton Conductivity (mS/cm) ≥ 140 ≥ 140 ≥ 140 ≥ 140
Alternative Options Pricing listed is calculated per square meter. For alternative roll parameters, precise pre-cut sheet dimensions, or technical lab testing quotes, please contact us.

Key Features & Advantages

  • Outstanding Proton Transfer Transport: Achieves a stable ionic benchmark of ≥ 140 mS/cm across all membrane variants, keeping gas production stacks highly efficient.
  • Full-Spectrum Structural Span: Covers a diverse thickness assortment ranging from 50 to 175 μm to reliably fit different voltage levels or custom research pressures.
  • High Dimensional Swelling Prevention: Delivers precise, restricted dimensional alteration parameters following hydration to protect stack perimeter seal structures.

APPLICATION SCOPE: Engineered specifically for high-capacity proton exchange membrane (PEM) water electrolysis systems, hydrogen generation rigs, and experimental gas production stacks.
PACKAGING: Hermetically vacuum-sealed inside climate-stabilized cleanroom zones utilizing custom moisture-barrier materials and sequential protective facing film interlayers.
IMPORTANT NOTICE: To guarantee absolute protection against localized membrane deformation, prevent any extended ambient drying exposure. Unsealed products should be kept inside vacuum-locked environmental storage compartments and operated strictly by qualified lab staff.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: INQUIRY@ATOMFAIR.COM
Manufacturer: ATOMFAIR LLC

This membrane requires strict humidity control to prevent dehydration-induced dimensional changes. Storage must be in vacuum-sealed, climate-stabilized environments to avoid localized deformation.

  • Dehydration Protection: Prevent any extended ambient drying exposure to avoid localized membrane deformation.
  • Storage Requirement: Unsealed membranes must be kept inside vacuum-locked environmental storage compartments.
  • Qualified Handling: Only qualified laboratory staff may operate the membrane to ensure safe installation.
  • Application Use: The membrane is engineered for high-capacity PEM water electrolysis and hydrogen generation systems.

This procedure ensures the membrane remains protected from ambient drying and maintains its dimensional integrity. Follow these steps to safely receive, store, and handle the membrane.

Required Equipment: Vacuum-locked environmental storage compartment, Climate-stabilized cleanroom zone

  1. Inspect Packaging
    Inspect the incoming membrane packaging for any visible damage or breaches to ensure the hermetic seal remains intact.
  2. Maintain Seal
    Keep the membrane sealed in its original moisture-barrier packaging until ready for use.
  3. Transfer Unsealed Membrane
    If the membrane is unsealed, transfer it immediately to a vacuum-locked environmental storage compartment.
  4. Verify Storage Conditions
    Verify that the storage area maintains climate-stabilized conditions to prevent ambient drying exposure.
  5. Ensure Qualified Handling
    Ensure that only qualified laboratory staff handle the membrane during installation.

What performance trade-off exists between membrane thickness and dimensional stability in the ELE-H series perfluorosulfonic acid membranes?

Thinner membranes (ELE-H050 at 50 μm, ELE-H080 at 80 μm) exhibit lower in-plane dimensional change (≤15% TD/MD) but higher thickness-direction swelling (≤45% and ≤40% respectively), while thicker variants (ELE-H120, ELE-H175) show balanced but higher in-plane change (≤25% TD/MD). All variants maintain a consistent proton conductivity of ≥140 mS/cm, so the trade-off is primarily in swelling anisotropy, which impacts stack sealing and stress distribution.

Are these perfluorosulfonic acid membranes designed for use in PEM fuel cells or exclusively for electrolysis applications?

The ELE-H series is engineered specifically for high-capacity proton exchange membrane (PEM) water electrolysis systems, hydrogen generation rigs, and experimental gas production stacks. The description does not indicate optimization for fuel cell operation, so use in PEM fuel cells is not supported by the stated application scope.

What storage and handling conditions are required to prevent localized deformation of the ELE-H membranes after unsealing?

To prevent localized membrane deformation, extended ambient drying exposure must be avoided. Unsealed products should be kept inside vacuum-locked environmental storage compartments and operated only by qualified lab staff. The membranes are supplied hermetically vacuum-sealed using moisture-barrier materials and protective film interlayers.

This series of perfluorosulfonic acid membranes (50–175 μm) delivers ≥140 mS/cm proton conductivity with controlled dimensional stability, but requires strict vacuum-sealed storage and handling to prevent deformation.

Positive

  • High Proton Conductivity Retention: All variants achieve ≥140 mS/cm proton conductivity, ensuring efficient hydrogen production in PEM electrolysis stacks.
  • Controlled Dimensional Swelling: Dimensional change is limited to ≤25% in-plane for all variants and ≤25% thickness for thicker films, with slightly higher thickness swelling for thinner variants, protecting stack perimeter seals.

Trade-offs

  • Moisture Sensitivity and Storage Requirements: Extended ambient drying exposure causes localized membrane deformation; requires vacuum-sealed storage and climate-controlled handling by qualified staff.
  • High Thickness Swelling in Thinner Variants: Thinner membranes (50, 80 μm) exhibit up to 45% thickness increase upon hydration, necessitating careful stack design to accommodate expansion and maintain seal integrity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Model

ELE-H175, ELE-H120, ELE-H080, ELE-H050