Laboratory Open-Cell Copper Foam, 80 PPI, 100 × 200 × 10 mm, 1/5 pcs
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For PPI selection, sheet-dimension confirmation, package support or application-specific configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Store the copper foam sheets in a clean, dry area to prevent contamination and oxidation of the open-cell structure. Protect the cellular surface from heavy impact, crushing, and contamination during handling and storage.
- Environmental Storage Requirement: Store sheets in a clean, dry environment to avoid moisture-induced oxidation and particulate contamination of the porous network.
- Mechanical Protection Requirement: Protect the open-cell structure from heavy impact or crushing forces that could collapse the interconnected pore network.
Inspect the delivered copper foam sheet for package condition, dimensional accuracy, and visible pore structure before use. Confirm that the sheet dimensions and pore density meet the application requirements prior to cutting or bonding.
Required Equipment: Clean, dry storage area, Calibrated ruler or caliper
- Inspect Package Condition
Inspect the package upon delivery for any signs of damage or contamination that could affect the foam sheet integrity. - Verify Sheet Dimensions
Measure the sheet length, width, and thickness with a calibrated ruler or caliper to confirm they match the specified 100 × 200 × 10 mm dimensions. - Examine Pore Structure
Visually examine the open-cell pore structure to ensure the through-pore network is intact and free from crushing or blockage. - Confirm Application Fit
Confirm that the 80 PPI pore density and sheet size are appropriate for the intended electrode, catalyst support, or filtration application before proceeding with integration.
How does the 80 PPI pore density correspond to the nominal pore pitch and porosity range of this copper foam?
The 80 PPI (pores per inch) corresponds to a nominal pore pitch of approximately 0.32 mm. The porosity is stated as 50–80%, meaning the void fraction can vary within that range while maintaining the same PPI. The bulk density ranges from 0.1 to 0.8 g/cm³, reflecting the porosity variation. This allows researchers to select a specific porosity within the 80 PPI structure for their application.
What is the significance of the ≥98% through-pore rate for filtration or electrode applications?
The ≥98% through-pore rate indicates that nearly all pores are interconnected and open from one surface to the other, minimizing dead-end pores. For filtration, this ensures high permeability and low pressure drop. For electrode frameworks, it guarantees maximum accessible surface area for electrochemical reactions and uniform electrolyte flow.
What storage and handling precautions are recommended for this open-cell copper foam sheet?
Store the sheets in a clean, dry area and protect the open cellular surface from heavy impact, crushing, and contamination. After delivery, inspect package condition, sheet dimensions, and visible pore structure before cutting, bonding, or installing. Avoid deformation that could collapse the interconnected pore network.
This 80 PPI open-cell copper foam sheet offers a high through-pore rate (≥98%) and defined 0.32 mm pore pitch for electrode, catalyst-support, and thermal-management evaluations, but requires careful handling to avoid structural damage and confirmation of exact porosity and bulk density for application-critical work.
Positive
- High through-pore connectivity: Stated through-pore rate of at least 98% ensures an interconnected open network that maximizes internal surface exposure for fluid flow, catalysis, and electrode current collection.
- Defined cellular geometry: 80 PPI with a nominal 0.32 mm pore pitch provides a reproducible cellular specification for engineering integration and laboratory comparisons.
Trade-offs
- Fragile open-cell structure: The open cellular surface must be protected from heavy impact, crushing, and contamination during storage and handling, as these can permanently deform or block the pore network.
- Specification variability: Porosity (50–80%) and bulk density (0.1–0.8 g/cm³) are stated as ranges; for application-critical integration, exact values must be confirmed before ordering to ensure fit.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).