Description
Mini TopPette Single-channel 200 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette is not suitable for high-temperature sterilization. Calibration must be performed according to ISO 8655-2 with verified compatible tips.
- Sterilization constraint: The pipette is not suitable for high-temperature sterilization.
- Calibration requirement: Calibration must be performed according to ISO 8655-2.
- Tip compatibility: Compatible tips must be confirmed before use to ensure stable tip fit and accurate liquid handling.
What are the systematic and random error specifications for the Atomfair Mini TopPette 200 µL fixed-volume pipette at its test volume?
At the 200 µL test volume, the systematic error is ±0.80 µL (±0.4%) and the random error is ±0.40 µL (±0.2%). These values are reported per the ISO 8655-2 calibration reference provided in the technical specification table.
Is the Mini TopPette 200 µL pipette suitable for high-temperature sterilization procedures?
No, according to the technical specifications this pipette is not suitable for high-temperature sterilization. It is designed for routine liquid transfer, assay setup, and sample preparation in workflows that do not require autoclaving.
What calibration standard does the Atomfair Mini TopPette 200 µL pipette comply with?
The pipette's calibration reference is ISO 8655-2, the international standard for piston-operated volumetric apparatus. Systematic and random error values are provided at the 200 µL test volume to allow users to verify performance against this standard.
The Mini TopPette Single-channel 200 µL Pipette delivers a fixed-volume, manual liquid handling solution with calibrated systematic error of ±0.80 µL (0.4%) and random error of ±0.40 µL (0.2%) at the 200 µL test point, suitable for single-tube sample preparation and routine analytical transfer, but limited by its lack of high-temperature sterilization compatibility and fixed-volume increment.
Positive
- Low systematic and random error: At the 200 µL test volume, systematic error is ±0.80 µL (±0.4%) and random error is ±0.40 µL (±0.2%), providing traceable accuracy per ISO 8655-2 for reproducible liquid handling in analytical workflows.
- Fixed volume for repeatability: The fixed 200 µL increment eliminates volume adjustment variability, ensuring consistent delivery across multiple transfers in PCR setup, serial dilution, or reagent addition protocols.
Trade-offs
- No high-temperature sterilization: The pipette is not suitable for autoclaving, requiring alternative decontamination methods (e.g., chemical disinfection) which may limit its use in sterile or adherent biohazard workflows.
- Fixed volume limits flexibility: The fixed 200 µL increment prevents volume adjustment, making the pipette unsuitable for protocols requiring variable volumes within the range; separate pipettes or adjustable models would be needed for multi-volume tasks.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).