Mini TopPette 10 μL Fixed-Volume Manual Pipette ATOMFAIR®

$4.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fixed-volume Mini TopPette single-channel 10 μL pipette with ISO 8655-2 calibration reference and ±0.08 μL systematic/random error. Order now.

SKU: AF-EI-L-MTOP-F010-SC00
Category: ,
Tags:
Brands:

Description

Mini TopPette Single-channel 10 µL Pipette

Product Type: Fixed-volume mini pipette
Research-grade liquid handling platform

Product Overview

Mini TopPette Single-channel 10 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 10 µL working range, Fixed volume increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 10 µL with Fixed volume increment.
  • Sterilization suitability: Not suitable for high-temperature sterilization.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MINI-TOPPETTE-10-µL
Product Family Mini TopPette
Channel count Single-channel
Volume range 10 µL
Increment Fixed volume
Test volume(s) 10 µL
Systematic error At 10 µL: ±0.08 µL (±0.8%)
Random error At 10 µL: ±0.08 µL (±0.8%)
Sterilization suitability Not suitable for high-temperature sterilization
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Fixed-volume pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette is incompatible with high-temperature sterilization and requires alternative low-temperature decontamination. Calibration according to ISO 8655-2 is necessary to ensure specified accuracy and precision.

  • Sterilization constraint: The pipette must not be sterilized by autoclaving or other high-temperature methods.
  • Calibration requirement: Routine user calibration per ISO 8655-2 is required to maintain systematic and random error within specified limits.

How does the fixed-volume design of the Mini TopPette 10 µL pipette affect its accuracy and repeatability compared to adjustable-volume pipettes?

The fixed-volume design eliminates user adjustment error, ensuring consistent performance at the single test volume of 10 µL. According to the technical specifications, systematic error is ±0.08 µL (±0.8%) and random error is ±0.08 µL (±0.8%) at 10 µL, both meeting ISO 8655-2 calibration standards. This makes it ideal for protocols requiring identical volume delivery every time, such as PCR or qPCR setup.

What sterilization methods are compatible with the Mini TopPette 10 µL pipette since it is not autoclavable?

The Mini TopPette 10 µL pipette is not suitable for high-temperature sterilization. Therefore, alternative non-thermal sterilization methods must be used, such as chemical disinfection with 70% ethanol or appropriate disinfectants, following laboratory safety protocols. The pipette is designed for routine liquid handling where autoclavable capability is not required.

What calibration procedures are required for the Mini TopPette 10 µL pipette to maintain ISO 8655-2 compliance?

The pipette is calibrated against the ISO 8655-2 user calibration reference as indicated in the technical specifications. Routine calibration should be performed at the single test volume of 10 µL, verifying that systematic error remains within ±0.08 µL and random error within ±0.08 µL. Users should follow the Atomfair calibration protocol or contact the technical sales team for method-specific volume matching and calibration planning.

Fixed-volume 10 µL pipette with ±0.08 µL systematic and random error (0.8%), designed for repetitive single-tube liquid transfers in research and teaching labs, but lacking high-temperature sterilization compatibility.

Positive

  • Fixed volume eliminates adjustment errors: The fixed 10 µL increment removes user-set volume variability, ensuring consistent delivery for repetitive tasks such as reagent addition or serial dilution.
  • Low error at 10 µL test volume: Systematic and random errors are both ±0.08 µL (±0.8%) at 10 µL, providing reliable precision for PCR setup and analytical transfers within the specified range.

Trade-offs

  • Not autoclavable: The pipette is not suitable for high-temperature sterilization, limiting decontamination options and requiring alternative disinfection methods for aseptic workflows.
  • Fixed volume lacks flexibility: The fixed 10 µL capacity restricts the pipette to a single volume; users must acquire additional instruments for other volumes, increasing inventory and cost for multi-volume protocols.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).