Description
Mini Pipette Single-channel 30 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This fixed-volume mini pipette requires calibration verification per ISO 8655-2 and is not suitable for high-temperature sterilization. Only compatible tips should be used to maintain accuracy and prevent damage.
- Sterilization constraint: Do not subject the pipette to high-temperature sterilization methods such as autoclaving.
- Calibration requirement: Calibration must be performed according to ISO 8655-2 using the 30 µL test volume to ensure systematic and random errors remain within specified tolerances.
- Tip compatibility: Use only tips confirmed compatible with the Atomfair Mini Pipette 30 µL to avoid leakage or inaccurate delivery.
- Error tolerance: Systematic error must not exceed ±1.00 µL and random error must not exceed ±0.50 µL at 30 µL for valid performance.
Given that the systematic error at 30 µL is ±1.00 µL (±0.4% of the test volume but 3.3% of the nominal volume), is this fixed-volume pipette acceptable for quantitative PCR or other high-precision analytical workflows?
For applications requiring ≤1% accuracy, this pipette may not be suitable. The source specifications at 30 µL report systematic error ±1.00 µL (±0.4% relative to test volume but 3.3% of the 30 µL set volume) and random error ±0.50 µL (±0.2%). These values exceed typical precision requirements for quantitative PCR or gravimetric analysis. The pipette is better suited for routine transfer, teaching labs, or reagent addition where absolute accuracy of ±3% is tolerable.
What pipette tip compatibility and sterilization options exist for this 30 µL fixed-volume mini pipette, and can it be used for aseptic cell culture work?
The pipette is explicitly marked as not suitable for high-temperature sterilization, so autoclaving is prohibited. For aseptic work, use sterile, DNase/RNase-free tips and surface decontaminate with 70% ethanol or appropriate disinfectant. The product description does not specify tip brand or design; users must confirm tip compatibility (e.g., universal, low-retention, or Atomfair brand tips) with the technical sales team before ordering to avoid fit issues.
What are the calibration and maintenance requirements for this fixed-volume 30 µL pipette given its ISO 8655-2 reference and lack of autoclavability?
Calibration must follow ISO 8655-2 user calibration reference as indicated in the technical table. Since the pipette cannot be autoclaved, decontamination requires chemical disinfection (e.g., 70% ethanol, 10% bleach solution) followed by air-drying. Routine maintenance should include periodic accuracy verification at the 30 µL test volume and tip ejection mechanism checks to maintain systematic and random error within ±1.00 µL and ±0.50 µL respectively.
The Atomfair Mini Pipette Single-channel 30 µL is a fixed-volume manual pipette with low systematic and random error per ISO 8655-2, but it cannot be autoclaved and lacks volume adjustment, limiting its application to dedicated 30 µL liquid handling under non-thermal sterilization protocols.
Positive
- High accuracy at 30 µL: Systematic error of ±1.00 µL (±0.4%) and random error of ±0.50 µL (±0.2%) at 30 µL, calibrated per ISO 8655-2, ensuring reliable liquid transfer for sensitive assays.
- Single-channel precision: Single-channel configuration provides controlled, repeatable liquid handling for individual sample preparation, PCR setup, and serial dilution workflows.
Trade-offs
- No high-temperature sterilization: Not suitable for autoclaving; decontamination is limited to chemical or low-temperature methods, which may affect workflow compatibility in sterile lab environments.
- Fixed volume restricts flexibility: Fixed volume increment of 30 µL means the pipette cannot be adjusted for other volumes, limiting its use to dedicated 30 µL applications only.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).