Description
Mini Pipette Single-channel 10 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This fixed-volume pipette is not autoclavable and requires calibration per ISO 8655-2. Tip compatibility must be verified to ensure proper fit and measurement accuracy.
- Sterilization Constraint: This pipette is not suitable for high-temperature sterilization; therefore, only low-temperature decontamination methods should be used.
- Calibration Requirement: The device must be calibrated per ISO 8655-2 user calibration reference to maintain systematic and random error specifications.
- Tip Compatibility: Compatible tips must be confirmed prior to use to prevent leakage or inaccurate volume delivery.
What are the accuracy limitations of using a fixed-volume 10 µL pipette compared to an adjustable pipette for applications requiring variable volumes?
The fixed-volume pipette delivers high repeatability at exactly 10 µL with a systematic error of ±0.08 µL (±0.8%) and random error of ±0.08 µL (±0.8%) at that single test volume, but it cannot be adjusted for other volumes. For variable-volume workflows, an adjustable pipette is required, though its error profile may differ at non-nominal set points.
Can the 10 µL fixed-volume mini pipette be used for PCR or qPCR setup, and what sterilization limitations apply?
Yes, the pipette is suitable for PCR and qPCR setup as stated in the product overview. However, it is not suitable for high-temperature sterilization, so aseptic workflows must rely on alternative sterilization methods such as chemical disinfection or UV treatment, or use of sterile filtered tips only.
What calibration checks are required for the Atomfair 10 µL fixed-volume mini pipette to maintain ISO 8655-2 compliance?
Per the ISO 8655-2 user calibration reference indicated in the technical table, users should perform routine gravimetric verification at the fixed test volume of 10 µL, comparing measured systematic and random error against the specified ±0.08 µL (±0.8%). Calibration planning should account for environmental conditions and regular maintenance schedules.
The Atomfair Mini Pipette Single-channel 10 µL is a fixed-volume manual pipette with specified accuracy of ±0.8% at 10 µL, ISO 8655-2 calibration, but lacks autoclavability and offers no volume adjustment flexibility.
Positive
- Specified accuracy at 10 µL: Systematic and random errors are both ±0.08 µL (±0.8%) at 10 µL, providing traceable performance for quantitative liquid handling.
- ISO 8655-2 calibration reference: Calibration follows ISO 8655-2, enabling laboratory compliance and method validation.
Trade-offs
- Not autoclavable: The pipette is not suitable for high-temperature sterilization, requiring alternative decontamination methods such as chemical disinfection.
- Fixed volume only: The pipette operates at a single fixed volume of 10 µL, limiting its use to applications requiring exactly that volume.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).