MicroPette Plus 5-50 μL Autoclavable Pipette ATOMFAIR®

$34.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable single-channel MicroPette Plus, 5-50 μL with 0.05 μL increments and ISO 8655-2 calibration reference; ±0.9% at 50 μL. Order now.

SKU: AF-EI-L-MCPL-E050-SC00
Category: ,
Tags:
Brands:

Description

MicroPette Plus Single-channel 5-50 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus Single-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-5-50-µL
Product Family MicroPette Plus
Channel count Single-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error At 50 µL: ±0.45 µL (±0.9%); at 25 µL: ±0.35 µL (±1.4%); at 5 µL: ±0.15 µL (±3.0%)
Random error At 50 µL: ±0.15 µL (±0.3%); at 25 µL: ±0.20 µL (±0.8%); at 5 µL: ±0.08 µL (±1.6%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy across its volume range. It is fully autoclavable and demands compatible tip selection for reliable performance.

  • Calibration Requirement: The pipette must be calibrated according to ISO 8655-2 at the specified test volumes to maintain systematic and random error tolerances.
  • Sterilization Suitability: The pipette is fully autoclavable, requiring confirmation of sterilization cycle parameters compatible with the manufacturer's recommendations.
  • Tip Compatibility: Compatible tips must be confirmed prior to use to ensure stable tip fit and accurate volume delivery.

How does the accuracy of the MicroPette Plus 5-50 µL pipette vary across its volume range?

Systematic error increases as a percentage of set volume at lower test volumes: at 50 µL it is ±0.45 µL (±0.9%), at 25 µL ±0.35 µL (±1.4%), and at 5 µL ±0.15 µL (±3.0%). Random error follows a similar trend, with ±0.15 µL (±0.3%) at 50 µL, ±0.20 µL (±0.8%) at 25 µL, and ±0.08 µL (±1.6%) at 5 µL, as specified in the technical table.

What tip compatibility and calibration requirements are needed for the MicroPette Plus 5-50 µL pipette?

The product documentation states that compatible tips must be confirmed before ordering and that the calibration reference is ISO 8655-2. No specific tip brand or model is listed, so users must verify tip fit for the 5–50 µL range and ensure calibration follows ISO 8655-2 user calibration procedures.

Can the MicroPette Plus 5-50 µL pipette be autoclaved without disassembly?

Yes, the pipette is described as fully autoclavable, meaning the entire instrument can be sterilized in an autoclave without requiring disassembly. This is suitable for routine decontamination in research and teaching laboratories.

This fully autoclavable single-channel manual pipette covers the 5–50 µL range with 0.05 µL increments and provides ISO 8655-2 traceable error specifications, making it suitable for routine liquid handling, PCR setup, and teaching labs, though accuracy at the 5 µL end is constrained by ±3.0% systematic error and its performance depends on compatible tips and regular calibration.

Positive

  • Fully autoclavable without disassembly: The entire pipette body can be sterilized by autoclaving, simplifying decontamination between uses and maintaining aseptic conditions in sensitive workflows.
  • Fine 0.05 µL increment for precise volume selection: The 0.05 µL increment over the 5–50 µL range allows fine adjustment of dispensed volumes, supporting method optimization and minimizing reagent waste in serial dilutions or assay setup.

Trade-offs

  • Requires compatible tips and periodic calibration: Optimal accuracy and tip retention depend on using manufacturer-recommended tips; the pipette must be calibrated regularly per ISO 8655-2 to maintain specified error limits.
  • Higher systematic error at low end of range: At 5 µL the systematic error is ±3.0% (versus ±0.9% at 50 µL), which limits absolute accuracy for very small volume transfers and may require volume correction or alternative methods for critical applications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).