Description

MicroPette Plus Single-channel 20-200 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus Single-channel 20-200 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 20-200 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 20-200 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 20-200 µL with 0.2 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-20-200-µL
Product Family MicroPette Plus
Channel count Single-channel
Volume range 20-200 µL
Increment 0.2 µL
Test volume(s) 200 / 100 / 20 µL
Systematic error At 200 µL: ±1.20 µL (±0.6%); at 100 µL: ±1.00 µL (±1.0%); at 20 µL: ±0.50 µL (±2.5%)
Random error At 200 µL: ±0.40 µL (±0.2%); at 100 µL: ±0.30 µL (±0.3%); at 20 µL: ±0.14 µL (±0.7%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy and precision. It is fully autoclavable for sterilization, but compatible tips must be selected to ensure proper fit and performance.

  • Calibration Requirement: Calibration must be performed according to ISO 8655-2 user calibration reference to verify systematic and random error at test volumes.
  • Sterilization Procedure: The pipette is fully autoclavable; follow manufacturer's sterilization guidelines to avoid damage.
  • Tip Compatibility: Compatible tips must be confirmed before use to ensure proper fit and avoid leakage or inaccurate volumes.

How does the systematic error of the MicroPette Plus 20-200 µL pipette vary across its volume range, and what is the trade-off between accuracy at high and low volumes?

Systematic error increases significantly at lower volumes: ±1.20 µL (±0.6%) at 200 µL, ±1.00 µL (±1.0%) at 100 µL, and ±0.50 µL (±2.5%) at 20 µL. This means relative accuracy degrades by a factor of over four from the maximum to minimum test volume, making the pipette most reliable near its upper range for applications requiring minimal systematic bias.

What calibration standard does the MicroPette Plus 20-200 µL pipette comply with, and how does that affect its integration into ISO-compliant workflows?

The pipette references ISO 8655-2 for user calibration, as stated in the technical table. This ensures traceable performance verification and supports integration into laboratories operating under ISO 17025 or GLP frameworks, provided users follow the specified test volumes (200, 100, 20 µL) and corresponding error limits for routine calibration checks.

What are the sterilization requirements for the MicroPette Plus 20-200 µL pipette, and does full autoclavability require any disassembly or special handling?

The pipette is fully autoclavable, as specified in the technical specifications. The product description does not detail disassembly steps or cycle parameters, so users should consult the manufacturer's instructions for proper autoclave preparation to avoid damage during sterilization.

The MicroPette Plus Single-channel 20-200 µL pipette offers fully autoclavable construction and ISO 8655-2 calibration traceability, but its single-channel format and relatively higher systematic error at 20 µL (±2.5%) should be considered for low-volume high-precision applications.

Positive

  • Fully autoclavable construction: The entire pipette can be autoclaved, enabling decontamination and safe use with biohazardous samples.
  • Calibration traceable to ISO 8655-2: Systematic and random error values are provided per test volume, allowing users to verify performance against an international standard.

Trade-offs

  • Higher systematic error at low volume: At 20 µL, the systematic error is ±2.5% (±0.50 µL), which may be limiting for applications requiring high accuracy at the lower end of the range.
  • Single-channel format limits throughput: The single-channel design is suited for single-tube tasks but not for parallel processing of multiple samples, requiring manual repetition for multiwell plates.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).