Description
MicroPette Plus 12-channel 30-300 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires full autoclave sterilization for decontamination between uses. Calibration must be verified against ISO 8655-2 using the specified test volumes to maintain accuracy.
- Sterilization Requirement: The pipette is fully autoclavable, requiring complete disassembly and sterilization at 121°C for 20 minutes to prevent cross-contamination.
- Calibration Constraint: Systematic and random error must be verified at 300, 150, and 30 µL test volumes per ISO 8655-2 to ensure traceable performance.
This procedure ensures the pipette is decontaminated and calibrated for accurate liquid handling. Follow these steps after routine use or before method setup.
Required Equipment: Autoclave, Calibration balance, Compatible pipette tips
- Disassemble pipette
Disassemble the pipette by removing the tip ejector and lower shaft assembly according to the manufacturer's instructions. - Autoclave components
Place all disassembled components in an autoclave bag and sterilize at 121°C for 20 minutes. - Reassemble and cool
Allow components to cool to room temperature, then reassemble the pipette ensuring all parts are dry and properly seated. - Verify calibration
Verify calibration by dispensing distilled water at 300, 150, and 30 µL test volumes onto a calibrated balance, comparing systematic and random error to ISO 8655-2 limits.
How does the performance of the MicroPette Plus 12-channel pipette vary between its highest and lowest test volumes?
The manufacturer provides systematic error and random error values at each of the three test volumes (300 µL, 150 µL, and 30 µL) for calibration review, allowing users to assess accuracy and precision trade-offs across the range. The pipette is calibrated per ISO 8655-2, and the technical table details these performance metrics for each test volume. At the lower end (30 µL), users should expect higher relative error compared to the upper end (300 µL), but the exact values are specified in the product's technical table.
What are the application compatibility requirements for using the MicroPette Plus 12-channel pipette in microplate and PCR workflows?
The 12-channel pipette is designed for microplate loading, PCR plate preparation, and ELISA workflows, but users must confirm compatible tips, calibration requirements, and sterilization needs before ordering. The pipette is fully autoclavable for sterilization between uses, and its 30-300 µL range with 5 µL increment supports standard parallel reagent transfer in these applications. For method-specific volume matching or accessory compatibility, contact the Atomfair technical sales team.
What sterilization method is recommended for the MicroPette Plus 12-channel pipette, and are there any post-sterilization handling requirements?
The MicroPette Plus 12-channel pipette is fully autoclavable, making it suitable for sterilization in standard laboratory autoclaves. After autoclaving, the pipette should be cooled and dried according to standard laboratory practice, and calibration should be verified if sterilization cycles are performed, as the product description does not specify a post-autoclave recalibration interval. The technical table notes that the pipette is fully autoclavable, but no special handling beyond routine drying is detailed.
The MicroPette Plus 12-channel 30-300 µL pipette offers a fully autoclavable, multichannel manual liquid handling solution suitable for high-throughput microplate and PCR workflows, but requires careful tip selection and external calibration verification per ISO 8655-2.
Positive
- Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling decontamination between uses in microbiological and molecular biology workflows.
- 12-channel high-throughput configuration: The 12-channel design allows simultaneous loading of 12 samples, significantly reducing time for microplate filling, PCR setup, and ELISA assays.
Trade-offs
- Requires compatible tips and calibration: The pipette does not include tips, and users must confirm tip compatibility and perform calibration according to ISO 8655-2 before deployment.
- Error values require separate reference table: Systematic and random error data are referenced in a technical table not included in this description, necessitating retrieval of the full specification document for accuracy verification.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).