Description
MicroPette Plus Single-channel 10-100 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette requires periodic calibration per ISO 8655-2 and is fully autoclavable for sterilization. Only compatible tips within the 10–100 µL range ensure accurate and repeatable liquid handling.
- Sterilization Requirement: The pipette must be autoclaved using standard laboratory cycles and allowed to cool completely before reuse to maintain integrity.
- Calibration Requirement: Calibration according to ISO 8655-2 is required to maintain the specified systematic and random error tolerances at each test volume.
- Tip Compatibility Constraint: Only pipette tips designed for the 10–100 µL range and that form a secure seal must be used to prevent inaccuracy and sample loss.
How does the relative systematic error of the MicroPette Plus 10-100 µL pipette vary across its test volumes, and what is the practical implication for low-volume pipetting?
The relative systematic error is ±0.8% at 100 µL, ±1.0% at 50 µL, and ±3.0% at 10 µL. This means accuracy degrades significantly at the lowest test volume. For applications requiring high precision at 10 µL, such as qPCR setup, users should consider using a lower-volume pipette or calibrating more frequently.
What ISO standard is referenced for the calibration of the MicroPette Plus pipette, and how does this support laboratory quality assurance?
The pipette calibration references ISO 8655-2, the international standard for piston-operated pipettes. This allows laboratories to perform in-house calibration checks using a defined procedure, ensuring traceability and compliance with quality management systems.
What is the sterilization capability of the MicroPette Plus pipette, and what precautions should be taken before and after autoclaving?
The pipette is fully autoclavable, meaning the entire unit can be sterilized. The product description does not specify autoclave parameters, so users should refer to the manual for recommended temperature and cycle times. After autoclaving, allow the pipette to cool and dry completely, and verify calibration before use, as thermal stress may affect accuracy.
The MicroPette Plus Single-channel 10-100 µL Pipette is a fully autoclavable manual pipette with ISO 8655-2 calibration reference, offering systematic error of ±0.8% at 100 µL and ±3.0% at 10 µL, making it suitable for routine liquid handling in research and teaching labs where sterilization and traceability are required.
Positive
- Fully autoclavable design: Entire pipette can be sterilized by autoclaving, facilitating decontamination between uses and extending service life in microbiology and molecular biology workflows.
- ISO 8655-2 calibration traceability: Systematic and random error values are provided at three test volumes, enabling users to evaluate performance against ISO 8655-2 standards for method validation and quality control.
Trade-offs
- Elevated systematic error at 10 µL: At the lower end of the volume range, systematic error reaches ±3.0%, which may limit suitability for applications requiring high accuracy below 20 µL without additional calibration adjustment.
- Tip compatibility and calibration dependency: Optimal performance requires confirmation of compatible tips and periodic calibration verification; performance may degrade with non-certified tips or extended calibration intervals.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).



