MicroPette Plus Pipette 0.5-10 μL ISO 8655 ATOMFAIR®

$34.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable single-channel MicroPette Plus pipette for 0.5-10 μL transfer, 0.01 μL increment and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-MCPL-B010-SC00
Category: ,
Tags:
Brands:

Description

MicroPette Plus Single-channel 0.5-10 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

MicroPette Plus Single-channel 0.5-10 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.5-10 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 0.5-10 µL working range, 0.01 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 0.5-10 µL with 0.01 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MICROPETTE-PLUS-0-5-10-µL
Product Family MicroPette Plus
Channel count Single-channel
Volume range 0.5-10 µL
Increment 0.01 µL
Test volume(s) 10 / 5 / 1 µL
Systematic error At 10 µL: ±0.10 µL (±1.0%); at 5 µL: ±0.08 µL (±1.5%); at 1 µL: ±0.03 µL (±2.5%)
Random error At 10 µL: ±0.04 µL (±0.4%); at 5 µL: ±0.04 µL (±0.8%); at 1 µL: ±0.02 µL (±1.8%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires periodic calibration per ISO 8655-2 to maintain accuracy within specified error limits. Full autoclaving at 121°C for 20 minutes is permitted for sterilization, but the pipette must be disassembled and dried before reassembly.

  • Calibration Constraint: Calibrate the pipette according to ISO 8655-2 using test volumes of 10 µL, 5 µL, and 1 µL to maintain specified systematic and random error limits.
  • Sterilization Constraint: Autoclave the pipette at 121°C for 20 minutes for full sterilization; ensure the pipette is fully disassembled and dried before reassembly.
  • Tip Compatibility Constraint: Use only compatible pipette tips designed for 0.5-10 µL volume range to ensure proper seal and accuracy.
  • Volume Range Constraint: Operate the pipette only within its specified volume range of 0.5-10 µL to avoid damage and maintain accuracy.
  • Error Tolerance Constraint: Monitor systematic error and random error at each test volume; replace or recalibrate if errors exceed specified limits.

Follow these steps for accurate liquid handling with the MicroPette Plus pipette. Proper technique ensures repeatability and prevents cross-contamination.

Required Equipment: Autoclave, Compatible pipette tips

  1. Set Volume
    Rotate the plunger button to set the desired volume within the 0.5-10 µL range using the 0.01 µL increment.
  2. Attach Tip
    Attach a compatible pipette tip firmly onto the shaft until a secure seal is achieved.
  3. Aspirate Liquid
    Depress the plunger to the first stop, immerse the tip vertically into the liquid, and slowly release the plunger to aspirate the set volume.
  4. Dispense Liquid
    Depress the plunger to the second stop to fully dispense the liquid into the target vessel.
  5. Eject Tip
    Press the tip ejector button to discard the used tip without touching it.
  6. Sterilize if Required
    Autoclave the pipette at 121°C for 20 minutes after disassembly if sterile conditions are needed.
  7. Calibrate Periodically
    Verify calibration using test volumes of 10 µL, 5 µL, and 1 µL according to ISO 8655-2.

How does the systematic error of the MicroPette Plus 0.5-10 µL pipette vary across its test volumes, and what implications does this have for low-volume measurements?

The systematic error at 10 µL is ±0.10 µL (±1.0%), at 5 µL is ±0.08 µL (±1.5%), and at 1 µL is ±0.03 µL (±2.5%). Relative error increases as volume decreases, indicating that accuracy is proportionally worse at the lower end of the range, which is critical for applications requiring precise microliter dispensing near 1 µL.

What calibration standard does the MicroPette Plus 0.5-10 µL pipette reference, and how does this affect user calibration verification?

The pipette is calibrated according to ISO 8655-2, as indicated in the technical table. Users should follow the ISO 8655-2 user calibration reference for performance verification, and the systematic and random error values listed at each test volume provide the basis for acceptance criteria.

Is the MicroPette Plus 0.5-10 µL pipette fully autoclavable without disassembly?

Yes, the pipette is specified as fully autoclavable, meaning the entire unit can be sterilized. The product description recommends confirming sterilization needs and calibration requirements before ordering, but does not detail specific disassembly steps or post-autoclave recalibration protocols.

This fully autoclavable single-channel pipette delivers 0.5-10 µL volumes with 0.01 µL increments and specified ISO 8655-2 accuracy and precision, making it suitable for PCR, qPCR, and analytical transfer in research and QC labs.

Positive

  • Fully autoclavable sterilization: The entire pipette can be autoclaved at 121°C without disassembly, enabling routine decontamination and reducing cross-contamination risk in molecular biology workflows.
  • Traceable ISO 8655-2 performance data: Systematic and random errors are specified at 10, 5, and 1 µL test volumes, providing calibration traceability for method validation and quality-control documentation.

Trade-offs

  • Manual operation requires skilled technique: As a manual pipette, consistent volume delivery depends on operator plunger speed and depth; not suitable for automated high-throughput workflows without retrofit.
  • Accuracy and precision degrade at low volumes: At 1 µL, systematic error reaches ±2.5% and random error ±1.8%, requiring careful volume matching and frequent calibration for critical assays in the sub-5 µL range.