Single-Channel Pipette 500–5000 μL Mi-Pette ATOMFAIR®

$58.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Single-channel Mi-Pette manual pipette, 500-5000 µL with 5 µL increment, ISO 8655-2 calibration reference, autoclavable design for QC labs. Order now.

SKU: AF-EI-L-MIPT-P5K0-SC00
Category: ,
Tags:
Brands:

Description

Mi-Pette Single-channel 500-5000 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette Single-channel 500-5000 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 500-5000 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 500-5000 µL working range, 5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 500-5000 µL with 5 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-500-5000-µL
Product Family Mi-Pette
Channel count Single-channel
Volume range 500-5000 µL
Increment 5 µL
Test volume(s) 5000 / 2500 / 500 µL
Systematic error At 5000 µL: ±40 µL (±0.8%); at 2500 µL: ±40 µL (±1.6%); at 500 µL: ±40 µL (±8.0%)
Random error At 5000 µL: ±15 µL (±0.3%); at 2500 µL: ±15 µL (±0.6%); at 500 µL: ±15 µL (±3.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette supports high-temperature sterilization as per the product family specification. Calibration must follow ISO 8655-2 user calibration reference with systematic and random error tolerances verified at test volumes.

  • Tip Compatibility: Only compatible tips must be used to ensure accurate volume delivery and stable tip fit.
  • Sterilization Conditions: High-temperature sterilization is supported but the specific parameters must be confirmed from the product family documentation.
  • Calibration Requirements: Calibration must follow ISO 8655-2 user calibration reference with systematic and random error verified at the indicated test volumes.

How does the systematic error of the Mi-Pette 500-5000 µL pipette change with volume, and what are the accuracy implications for low-volume measurements?

The systematic error is constant at ±40 µL across all test volumes, resulting in a percentage error that increases sharply at lower volumes: ±0.8% at 5000 µL, ±1.6% at 2500 µL, and ±8.0% at 500 µL. This means accuracy degrades significantly at the low end of the range, making the pipette best suited for applications where near-full-range volumes are used, or where error tolerance can accommodate the higher relative inaccuracy at 500 µL.

What calibration and tip compatibility requirements must be met to ensure ISO 8655-2 compliance for the Mi-Pette 500-5000 µL pipette?

The pipette includes a user calibration reference per ISO 8655-2, so routine calibration should follow that standard. The product description notes that compatible tips must be confirmed before use, and calibration planning is recommended. For method setup, the systematic and random error data at 5000, 2500, and 500 µL are provided to support volume-specific accuracy checks, but tip fit and seal integrity must be verified separately to maintain compliance.

What is the recommended autoclave sterilization procedure for the Mi-Pette 500-5000 µL pipette, and does it require recalibration after sterilization?

The Mi-Pette 500-5000 µL pipette is fully autoclavable and supports high-temperature sterilization. The product description does not specify a particular cycle, so users should follow the manufacturer's instructions for sterilization parameters. Because thermal cycling can affect mechanical calibration, it is prudent to verify calibration after each sterilization cycle, though the source does not mandate recalibration.

The Mi-Pette Single-channel 500–5000 µL pipette offers a wide adjustable volume range with fine 5 µL increments and full autoclavability for sterility assurance; however, accuracy degrades markedly at the lower end of its range (systematic error ±8.0% at 500 µL), which imposes a practical constraint on low-volume precision work.

Positive

  • Wide volume range with fine increment: The pipette covers 500–5000 µL in 5 µL steps, enabling precise adjustment across a broad working range suitable for diverse liquid handling tasks.
  • Fully autoclavable construction: High-temperature sterilization is supported where indicated by the source family, allowing decontamination between uses without disassembly.

Trade-offs

  • High systematic error at low volumes: At the minimum test volume of 500 µL systematic error reaches ±40 µL (±8.0%), significantly reducing absolute accuracy for small-volume transfers.
  • Elevated random error at low volumes: Random error at 500 µL is ±15 µL (±3.0%), which may compromise repeatability in applications requiring tight precision near the lower end of the range.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).