Description
Mi-Pette 12-channel 0.5-10 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette requires periodic calibration traceable to ISO 8655-2 to maintain specified accuracy at each test volume. The device supports high-temperature sterilization only when explicitly indicated by the source family for the specific model.
- Calibration Requirement: Calibration must be performed according to ISO 8655-2 using the test volumes 10 µL, 5 µL, and 1 µL to verify systematic and random error limits.
- Sterilization Compatibility: High-temperature sterilization is supported only for models within the source family that explicitly indicate compatibility; confirm prior to autoclaving.
- Tip Compatibility: Compatible tip selection is required to achieve specified accuracy and prevent leakage during multichannel operations.
What is the systematic error of the Mi-Pette 12-channel 0.5-10 µL pipette at the 1 µL test volume, and how does this affect reproducibility for low-volume assays?
The systematic error at 1 µL is ±0.24 µL (±24%), and the random error is ±0.16 µL (±16%). These relatively high percentages indicate that the pipette is less accurate and precise at the lower end of its range, so for low-volume assays requiring high reproducibility, users should consider using a pipette with a narrower volume range or calibrate more frequently at the 1 µL setting.
Does the Mi-Pette 12-channel pipette comply with ISO 8655-2, and how can users perform routine calibration?
Yes, the pipette's calibration reference is ISO 8655-2, as indicated in the technical table. The manufacturer provides a user calibration reference, meaning users can perform routine calibration according to the standard. For specific calibration procedures, contact the technical sales team.
What sterilization conditions are recommended for the Mi-Pette 12-channel 0.5-10 µL pipette, and is it fully autoclavable?
The pipette supports high-temperature sterilization where indicated by the source family. The technical table lists sterilization suitability as high-temperature sterilization supported. Users should confirm that the specific model is autoclavable and follow the manufacturer's instructions to avoid damage. Contact Atomfair for validation.
This 12-channel pipette offers efficient parallel liquid handling in the 0.5-10 µL range with full autoclavability, but its accuracy and precision degrade significantly at the lower end of the volume range, especially at 1 µL.
Positive
- 12-channel parallel liquid handling: Facilitates efficient microplate filling, PCR setup, and ELISA workflows by allowing simultaneous transfer of 12 samples, significantly reducing processing time.
- Full autoclavability for sterilization: The entire pipette can withstand high-temperature sterilization, enabling decontamination and reuse in aseptic laboratory environments without disassembly.
Trade-offs
- High relative error at low end of range: Systematic error of ±24% and random error of ±16% at 1 µL limit the pipette's reliability for accurate dispensing near its lower volume limit.
- Requires verification of sterilization compatibility: Sterilization suitability is stated as supported where indicated by source family, not explicitly confirmed for this model; users must verify before autoclaving.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).