Infrared Oil Analyzer PIO 563, 0.02–8000mg/L ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Portable PIO 563 infrared oil analyzer measures 0.02–8000mg/L without dilution, with ±3% accuracy, <0.2mg/L detection limit, and 8+ hours battery life.

SKU: AFMSMJMS214
Category:
Brands:

 

Atomfair PIO 563 Portable Infrared Photometric Oil Analyzer

Product Overview

Atomfair PIO 563 Portable Infrared Photometric Oil Analyzer boasts a compact size, light weight, and a detachable integrated optical path design, enabling easy portability. It meets international infrared spectral standards with excellent stability and high signal-to-noise ratio. Widely applied for the determination of petroleum, animal and vegetable oils in industrial wastewater and domestic sewage, it delivers reliable detection support for both on-site and laboratory scenarios.

Core Product Features

  1. Exceptional Portability: Equipped with an exclusive safety protection case, it is convenient to carry and flexible to operate, perfectly suitable for mobile work scenarios like field operations.
  2. Efficient Opto-Electronic System: Adopts a pulse light source to effectively reduce light source heating intensity, facilitating system heat dissipation and enhancing instrument reliability as well as component service life. The pre-integrated narrow-band active filter and digital phase-locked amplifier significantly improve the signal-to-noise ratio, ensuring more stable instrument performance.
  3. Real-Time Automatic Zero Adjustment: The instrument collects signals separately when the light source flashes on and off, realizing real-time automatic zero adjustment, simplifying the operation process, and guaranteeing stable long-term operation of the instrument.
  4. Long Continuous Measurement Time: Equipped with a high-power battery, it can perform continuous measurement for over 8 hours and supports connection to automobile power supply, making on-site measurement more convenient and efficient.
  5. Compatibility with Multiple Extractants: Compatible with various extractants such as tetrachloroethylene, carbon tetrachloride, S316, and trichlorotrifluoroethane, meeting different detection requirements.
  6. User-Friendly Operation: Features a large touch screen with intuitive operation, supporting both standalone use and computer connection for collaborative work, lowering the operational threshold.

Technical Specifications

Technical Index Specific Parameters
Wavenumber Scanning Range 3400cm⁻¹ – 2400cm⁻¹ (2.5-4.0µm)
Wavenumber Accuracy ±1cm⁻¹
Wavenumber Repeatability ±1cm⁻¹
Spectral Resolution 1cm⁻¹
Measurement Repeatability <3%
Measurement Accuracy ±3%
Absorbance Linear Range 0.0000~1.9999AU
Correlation Coefficient r>0.999 (Infrared Non-Dispersive Method)
Measurement Range 0.02~8000mg/L (Direct Measurement Without Dilution)
Detection Limit (3SD) <0.2mg/L (Solution Concentration)
Overall Dimensions 390×370×240mm
Weight 19kg
Power Supply DC 12V 10Ah Lithium Battery, AC 220V±10%
Operating Humidity <80%
Operating Temperature 5-35°C

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

How does the Atomfair PIO 563 achieve its high signal-to-noise ratio and stable performance?

The PIO 563 uses a pulse light source to reduce heating intensity, combined with a pre-integrated narrow-band active filter and a digital phase-locked amplifier to significantly improve the signal-to-noise ratio. This opto-electronic design ensures stable instrument performance and reliable detection for oil analysis in wastewater.

What extractants are compatible with the PIO 563 and does it require re-calibration when switching between them?

The instrument is compatible with tetrachloroethylene, carbon tetrachloride, S316, and trichlorotrifluoroethane. Its real-time automatic zero adjustment system, which collects signals separately when the light source flashes on and off, simplifies the operation and eliminates the need for manual recalibration when switching extractants.

What are the environmental and power requirements for operating the PIO 563 in field conditions?

The PIO 563 operates in ambient temperatures of 5–35°C and humidity below 80%. It is powered by a DC 12V 10Ah lithium battery that supports over 8 hours of continuous measurement, and it can also be connected to an automobile power supply, making it suitable for extended field operations.

The Atomfair PIO 563 Portable Infrared Photometric Oil Analyzer delivers a 1 cm⁻¹ spectral resolution across 3400–2400 cm⁻¹, enabling direct measurement of petroleum and animal/vegetable oils in water from 0.02 to 8000 mg/L without dilution, with a detection limit below 0.2 mg/L. Its pulse light source, digital phase-locked amplifier, and real-time automatic zero adjustment ensure stable, high signal-to-noise performance in field and laboratory settings.

Positive

  • Wide direct measurement range: The 0.02–8000 mg/L measurement range without dilution covers trace to high-concentration oil contamination in a single run, reducing sample preparation time and potential errors.
  • Stable opto-electronic design: The pulse light source reduces heating, while the pre-integrated narrow-band active filter and digital phase-locked amplifier improve signal-to-noise ratio, ensuring reliable and repeatable absorbance readings.

Trade-offs

  • Environmental operating limits: The instrument requires an operating temperature of 5–35°C and humidity below 80%, restricting use in extreme or uncontrolled field environments without additional climate protection.
  • Extractant compatibility constraints: Although multiple extractants are supported, the choice of extractant affects measurement accuracy and must be matched to the sample matrix, requiring method validation for each new solvent.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).