HiPette-LTS 8-Channel 20-200 μL Manual Pipette ATOMFAIR®

$300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette-LTS 8-channel manual pipette, 20-200 μL range with 0.2 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HPLT-H200-08CH
Category: ,
Tags:
Brands:

Description

HiPette-LTS 8-channel 20-200 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 8-channel 20-200 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 20-200 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 20-200 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 20-200 µL with 0.2 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-8CHANNEL-20-200-µL
Product Family HiPette-LTS
Channel count 8-channel
Volume range 20-200 µL
Increment 0.2 µL
Test volume(s) 200 / 100 / 20 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette requires sterilization by autoclaving and calibration per ISO 8655-2. Tip compatibility must be confirmed prior to use to ensure proper fit and accuracy.

  • Sterilization Requirement: The pipette is fully autoclavable; repeated sterilization cycles should follow manufacturer guidelines to maintain integrity.
  • Calibration Reference: Calibration must be performed according to ISO 8655-2 using test volumes of 200, 100, and 20 µL to verify systematic and random errors.
  • Tip Compatibility: Only pipette tips confirmed compatible with the LTS mechanism should be used to avoid leakage or inaccurate volume delivery.
  • Error Specifications: Systematic and random error values are specified for each test volume and should be monitored during routine performance verification.

What is the systematic error and random error at the lower end (20 µL) compared to the upper end (200 µL) of the volume range?

The product description lists test volumes of 200, 100, and 20 µL, but does not provide the exact systematic error or random error values. According to ISO 8655-2 calibration, these values are retained in the technical table. Users should consult the table for specific error data at each test volume to assess performance trade-offs across the range.

What types of tips are compatible with the HiPette-LTS 8-channel 20-200 µL pipette?

The product description indicates that compatible tips are required, but specific tip models are not listed. Users should select tips that match the 20-200 µL volume range and 8-channel format, and contact the Atomfair technical sales team for verified compatibility recommendations to ensure stable tip fit and repeatability.

How should the HiPette-LTS 8-channel pipette be sterilized?

The pipette is fully autoclavable, allowing complete sterilization. No specific autoclave cycle parameters are provided, so standard autoclave procedures for laboratory equipment should be followed. Ensure the pipette is disassembled as per manufacturer instructions before autoclaving to maintain calibration and performance.

The HiPette-LTS 8-channel 20-200 µL pipette is a fully autoclavable manual multichannel pipette designed for high-throughput microplate and PCR workflows, with systematic and random error values specified per test volume for ISO 8655-2 traceable calibration.

Positive

  • Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling decontamination between assays or when handling biohazardous materials without disassembly.
  • ISO 8655-2 calibration reference: Systematic and random error values are provided per test volume (200, 100, 20 µL), allowing direct verification of accuracy and precision against the international standard for piston-operated volumetric apparatus.

Trade-offs

  • Requires compatible tip selection: Optimal performance depends on using tips that match the 8-channel format and volume range; incompatible tips may compromise seal integrity and accuracy.
  • Manual operation limits throughput: As a manual pipette, repeated use in high-throughput workflows may introduce operator fatigue and variability compared to electronic alternatives.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).