Manual HiPette-LTS 8-Channel 30-300 μL Pipette ATOMFAIR®

$300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable 8-channel manual pipette with 30-300 μL range, 0.2 μL increment and ISO 8655-2 calibration reference for microplate workflows. Order now.

SKU: AF-EI-L-HPLT-J300-08CH
Category: ,
Tags:
Brands:

Description

HiPette-LTS 8-channel 30-300 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 8-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 30-300 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 0.2 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-8CHANNEL-30-300-µL
Product Family HiPette-LTS
Channel count 8-channel
Volume range 30-300 µL
Increment 0.2 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette requires validated sterilization cycles and calibration per ISO 8655-2 to maintain accuracy and tip seal integrity. Users must confirm tip compatibility, autoclave parameters, and calibration schedules before routine laboratory use.

  • Sterilization Compatibility: Autoclaving must be performed on the fully disassembled pipette at the manufacturer-recommended temperature and duration to ensure sterility without distorting internal components.
  • Calibration Reference: Calibration must be carried out gravimetrically at the specified test volumes (300 µL, 150 µL, 30 µL) in accordance with ISO 8655-2 to guarantee stated systematic and random error limits.
  • Tip Compatibility: Only LTS-style multichannel pipette tips from validated suppliers must be used to achieve proper sealing, volume accuracy, and leak-free dispensing.
  • Volume Range Limitation: The pipette must not be operated outside its 30–300 µL volume range to prevent piston over-travel and irreversible calibration drift.

How does the systematic error of the HiPette-LTS 8-channel 30-300 µL pipette vary across its volume range?

The systematic error is specified per test volume (300, 150, and 30 µL) in the technical table, with calibration reference to ISO 8655-2. Exact values are retained in the product documentation for procurement and method setup. The pipette uses a 0.2 µL increment and is designed for repeatable parallel reagent transfer.

What type of pipette tips are compatible with the HiPette-LTS 8-channel 30-300 µL pipette?

The product description advises confirming compatible tips before ordering, but does not specify a particular tip brand or model. The pipette is designed for 30-300 µL volume range and 8-channel format, so tips appropriate for that volume range and multichannel configuration are required. Contact Atomfair technical sales for specific tip matching and accessory compatibility.

What sterilization method is recommended for the HiPette-LTS 8-channel pipette?

The pipette is fully autoclavable, making it suitable for sterilization in research, quality-control, and teaching laboratories. No other sterilization methods are specified. Autoclaving ensures aseptic handling for microplate loading, PCR plate preparation, and ELISA workflows.

The HiPette-LTS 8-channel 30-300 µL pipette is a fully autoclavable manual pipette designed for parallel liquid handling in microplate and PCR workflows, with systematic error data provided per ISO 8655-2 for calibration traceability.

Positive

  • Fully autoclavable sterilization: The entire pipette can be autoclaved, enabling complete decontamination between experiments or when handling biohazardous materials.
  • 8-channel parallel processing: The 8-channel configuration supports simultaneous liquid transfer in microplate, PCR plate, and ELISA workflows, increasing throughput and repeatability.

Trade-offs

  • Tip and calibration dependency: Compatible tips and routine calibration per ISO 8655-2 must be confirmed before use; accuracy depends on tip fit and adherence to the calibration schedule.
  • Volume range limitation: The working range of 30–300 µL with a 0.2 µL increment restricts use to mid-range volumes; not suitable for sub-10 µL or above 300 µL applications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.