Description
HiPette-LTS Single-channel 0.1-2.5 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires calibration per ISO 8655-2 to maintain accuracy. It is designed for full autoclave sterilization for decontamination.
- Calibration: The pipette must be calibrated using the reference method ISO 8655-2 at the designated test volumes to ensure systematic and random error remain within specified limits.
- Sterilization: The pipette is fully autoclavable for sterilization between uses.
- Tip Compatibility: Only tips designed for the HiPette-LTS single-channel pipette should be used to maintain accurate volume delivery and tip retention.
What is the accuracy performance of the HiPette-LTS 0.1-2.5 µL pipette at volumes near its lower limit, and how does it compare to the mid-range?
At 2.5 µL, systematic error is ±0.04 µL (±1.4%). At 1.25 µL, it is ±0.03 µL (±2.5%). At 0.25 µL, systematic error increases to ±0.03 µL (±12.0%), indicating a significant accuracy trade-off at the low end of the range. Users should avoid using the pipette near its minimum volume for precision-critical applications.
What calibration standard does the HiPette-LTS 0.1-2.5 µL pipette comply with, and what must be confirmed before ordering?
The pipette is calibrated per ISO 8655-2. Before ordering, users must confirm compatible tips, calibration requirements, sterilization needs, and laboratory workflow to ensure proper integration.
Is the HiPette-LTS 0.1-2.5 µL pipette sterilizable, and what method is recommended?
Yes, the pipette is fully autoclavable. No specific autoclave cycle parameters are provided, but standard sterilization procedures for manual pipettes are applicable. The pipette is designed for routine decontamination between uses.
This 0.1-2.5 µL single-channel pipette offers full autoclavability and fine 0.002 µL increment, but the systematic error at the lowest test volume (0.25 µL) reaches ±12.0%, requiring careful volume selection for precise applications.
Positive
- Full autoclavability without disassembly: The pipette is fully autoclavable, enabling complete sterilization in situ for contamination-sensitive workflows such as PCR setup and clinical sample handling.
- Fine 0.002 µL volume increment: The 0.002 µL increment allows precise volume adjustment within the sub-microliter range, supporting method-specific dispensing for high-dilution assays and low-volume reagent addition.
Trade-offs
- High systematic error at low test volume: At 0.25 µL the systematic error is ±12.0%, significantly reducing absolute accuracy for applications requiring precise dispensing at the lower end of the range; users should operate above this volume if tighter tolerances are needed.
- Requires tip and calibration confirmation: Compatible pipette tips and calibration schedule must be confirmed before deployment, as tip fit and periodic recalibration directly affect performance and traceability per ISO 8655-2.