Description
HiPette-LTS Single-channel 2-20 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires sterilization by autoclaving and calibration per ISO 8655-2. Only compatible tips must be used to maintain accuracy and prevent damage.
- Sterilization Constraint: The pipette is fully autoclavable and must be sterilized at standard autoclave conditions to prevent cross-contamination.
- Calibration Constraint: Calibration verification must be performed at the specified test volumes to confirm systematic and random error are within the published limits.
- Tip Compatibility Constraint: Only compatible tips designed for the HiPette-LTS series must be used to ensure proper seal and accurate volume delivery.
How does the accuracy of the HiPette-LTS 2-20 µL pipette vary across its volume range, particularly at the lower end?
The systematic error increases significantly at the lower end of the range. At 20 µL, the systematic error is ±0.20 µL (±1.0%). At 2 µL, it is ±0.10 µL (±5.0%), indicating a five-fold relative error increase. The random error at 2 µL is ±0.03 µL (±1.5%). These values are specified in the technical table.
What tip system is compatible with the HiPette-LTS single-channel pipette?
The HiPette-LTS pipette is designed for use with LTS (Low Tip Seal) compatible tips, as indicated by the model designation. The product description emphasizes confirming compatible tips before ordering, and the product family is specific to the LTS tip system.
Can the HiPette-LTS 2-20 µL pipette be sterilized, and what method is recommended?
Yes, the HiPette-LTS is fully autoclavable, meaning the entire pipette can be sterilized in an autoclave. This is explicitly stated in the product specifications and key features. No other sterilization methods are mentioned, so autoclaving is the recommended approach.
The HiPette-LTS 2–20 µL manual pipette offers full autoclavability and low random error across its range, but accuracy degrades to ±5.0% at the 2 µL lower limit and requires careful tip selection and routine calibration for consistent performance.
Positive
- Fully autoclavable for sterilization: The entire pipette can be autoclaved without disassembly, enabling aseptic technique in PCR setup and microbiology workflows.
- Low random error across the range: Random error remains ≤±0.06 µL (0.3%) at 20 µL and ≤±0.03 µL (1.5%) at 2 µL, supporting reproducible liquid transfers in routine assays and serial dilutions.
Trade-offs
- Elevated systematic error at 2 µL: Systematic error reaches ±5.0% at the 2 µL test volume, which may limit accuracy for low-volume applications such as enzyme master mix preparation.
- Requires compatible tips and user calibration: Performance depends on selecting properly fitting tips and adhering to ISO 8655-2 calibration checks; improper tip fit or skipped calibration compromises accuracy and precision.