Description
HiPette-LTS 12-channel 5-50 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires sterilization via autoclaving to prevent contamination. Calibration according to ISO 8655-2 is necessary to maintain specified accuracy across test volumes.
- Sterilization Requirement: The pipette must be fully autoclaved between uses to eliminate cross-contamination from previous samples.
- Calibration Procedure: Calibrate the pipette per ISO 8655-2 using the test volumes 50 µL, 25 µL, and 5 µL to verify systematic and random error limits.
- Tip Compatibility: Only use pipette tips explicitly designed for the HiPette-LTS 12-channel to ensure proper seal and volume accuracy.
How does the pipette's accuracy vary across the 5-50 µL volume range?
The pipette's accuracy is specified at three test volumes (50, 25, and 5 µL) with systematic and random error values provided per test volume. The 0.05 µL increment supports fine adjustments, and accuracy is validated per ISO 8655-2 user calibration reference, allowing performance evaluation across the high, mid, and low end of the range.
What specific laboratory applications is the 12-channel 5-50 µL pipette optimized for?
The pipette is optimized for microplate loading, PCR plate preparation, ELISA workflows, and repeated parallel reagent transfer. Its 12-channel configuration and 5-50 µL range make it directly compatible with 96-well microplates and standard multichannel protocols. Users must confirm compatible tips and calibration requirements before workflow integration.
What are the sterilization requirements and infrastructure needed for the HiPette-LTS pipette?
The pipette is fully autoclavable for sterilization, requiring only standard autoclave equipment. For calibration, the pipette references ISO 8655-2 user calibration, so users should plan routine calibration schedules. No specialized infrastructure beyond typical lab autoclave and calibration tools is required.
The HiPette-LTS 12-channel 5-50 µL pipette is a fully autoclavable manual pipette designed for high-throughput microplate and PCR workflows, with a 0.05 µL increment and ISO 8655-2 calibration reference, but requires compatible tips and routine calibration verification for sustained accuracy.
Positive
- Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling decontamination between uses in sensitive workflows such as PCR and cell culture without disassembly.
- 12-channel parallel liquid transfer: The 12-channel format supports efficient microplate loading, PCR plate preparation, and ELISA workflows, reducing handling time for repeated parallel reagent transfers.
Trade-offs
- Requires compatible tip selection: The pipette's performance depends on using compatible tips; incorrect tip fit can compromise seal integrity and volumetric accuracy, requiring pre-order confirmation.
- Calibration verification needed periodically: Systematic and random error values are provided per test volume, but routine calibration checks per ISO 8655-2 are necessary to maintain specified accuracy over time.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).



