Description
HiPette-LTS Single-channel 0.5-10 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The HiPette-LTS single-channel pipette requires regular calibration per ISO 8655-2 and full autoclave sterilization for routine use. Tip compatibility and volume increment settings must be confirmed before operation to maintain accuracy.
- Sterilization Requirement: The pipette is fully autoclavable for decontamination between uses.
- Calibration Requirement: Calibration must be performed against ISO 8655-2 at the specified test volumes of 10, 5, and 1 µL to maintain accuracy.
How does the systematic error of the HiPette-LTS 0.5-10 µL pipette degrade at lower volumes, and what is the practical impact on assay reproducibility?
At 10 µL, the systematic error is ±0.10 µL (±1.0%), while at 1 µL it increases to ±0.03 µL (±2.5%). The random error also rises from ±0.04 µL (0.4%) at 10 µL to ±0.02 µL (1.8%) at 1 µL. These values indicate that accuracy degrades at the lower end of the range, which must be accounted for in method validation for low-volume applications like PCR setup.
What are the recommended calibration and workflow considerations when using the HiPette-LTS 0.5-10 µL pipette for PCR or qPCR setup?
The pipette is suitable for PCR and qPCR setup, but the user must confirm compatible tips, calibration requirements, and sterilization needs before use. The calibration reference is ISO 8655-2, and the systematic error at 1 µL is ±2.5%, which is critical for single-digit microliter transfers in PCR. Full autoclavability allows sterilization between runs to prevent cross-contamination.
What sterilization infrastructure is required for the HiPette-LTS 0.5-10 µL pipette, and does autoclavability affect the pipette's performance over time?
The pipette is fully autoclavable, requiring no disassembly for sterilization. The technical specifications confirm sterility suitability, but no specific autoclave cycle parameters are provided. Users should refer to the ISO 8655-2 calibration reference after sterilization to ensure the systematic and random error values remain within specification.
This single-channel 0.5-10 µL pipette delivers full autoclavability and certified error data across three test volumes, supporting reliable PCR and microvolume sample preparation. Its limited volume range and need for tip matching and calibration management are key operational considerations.
Positive
- Fully autoclavable for sterilization: The entire pipette can be autoclaved at 121°C, facilitating decontamination and preventing cross-contamination in sensitive workflows.
- Calibration data provided per test volume: Systematic and random errors are specified at 10 µL, 5 µL, and 1 µL, enabling users to assess precision and accuracy for their target volumes.
Trade-offs
- Narrow volume range limits versatility: The 0.5-10 µL range restricts use to micro-volume applications; laboratories handling larger volumes require separate pipettes.
- Requires compatible tips and calibration planning: Users must verify tip compatibility and schedule periodic calibration as per ISO 8655-2, adding procedural overhead.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).