HiPette 12-Channel Manual Pipette 5-50 μL ISO 8655 ATOMFAIR®

$365.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette 12-channel manual pipette, 5-50 μL range with 0.05 μL increment and ISO 8655-2 calibration reference for PCR. Order now.

SKU: AF-EI-L-HIPP-E050-12CH
Category: ,
Tags:
Brands:

Description

HiPette 12-channel 5-50 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette 12-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-12CHANNEL-5-50-µL
Product Family HiPette
Channel count 12-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires careful calibration and tip selection to achieve accurate liquid handling. It must be used within its volume range and calibrated at specified test volumes.

  • Tip Compatibility: Use only 12-channel pipette tips rated for 5-50 µL to ensure proper fit and accuracy.
  • Calibration Requirements: Calibrate the pipette at test volumes of 50, 25, and 5 µL following ISO 8655-2 to maintain specified error limits.
  • Volume Range: Operate the pipette only within the 5-50 µL volume range to avoid mechanical stress and ensure dispensing precision.

How does the systematic error of the HiPette 12-channel 5-50 µL pipette vary across the three test volumes (50, 25, 5 µL), and what impact does this have on low-volume pipetting accuracy?

The systematic error values are provided for each test volume (50, 25, 5 µL) in the technical table; users should consult these values to assess accuracy at their working volume. At the lowest test volume (5 µL), the relative error contribution is larger than at 50 µL, so the pipette is best suited for mid- to high-volume applications within the 5–50 µL range. The 0.05 µL increment allows fine adjustment, but performance at low microliter volumes depends on the specific systematic error listed in the supplied table.

What type of tips are compatible with the HiPette 12-channel 5-50 µL pipette, and does the fully autoclavable design affect tip compatibility or require special handling after sterilization?

The product description states that users must confirm compatible tips before ordering; no specific tip brand or model is listed. The pipette is fully autoclavable, meaning the entire unit can be sterilized without disassembly, but tips must be removed before autoclaving. After sterilization, the pipette should be allowed to cool and dry completely before use with fresh tips to maintain proper fit and accuracy.

What calibration standard does the HiPette 12-channel 5-50 µL pipette comply with, and how frequently should calibration be performed to maintain ISO 8655-2 compliance in a regulated laboratory?

The pipette complies with ISO 8655-2, which provides a user calibration reference. The product description does not specify a calibration interval, but typical laboratory practice requires calibration every 3–12 months depending on usage frequency and regulatory requirements. The technical table includes systematic and random error values for each test volume (50, 25, 5 µL) to facilitate routine calibration checks against the ISO 8655-2 standard.

The HiPette 12-channel 5-50 µL pipette offers a parallel liquid handling platform with full autoclavability and calibration traceability to ISO 8655-2, suitable for high-throughput microplate and PCR workflows. The user must verify tip compatibility and manage periodic calibration to maintain specified accuracy.

Positive

  • 12-channel parallel pipetting for high-throughput workflows: The 12-channel configuration enables simultaneous parallel liquid transfer, significantly speeding up microplate loading, PCR plate preparation, and ELISA workflows compared to single-channel alternatives.
  • Fully autoclavable for sterilization and decontamination: The entire pipette withstands autoclaving, allowing complete sterilization between uses to prevent cross-contamination in sensitive biological and clinical assays.

Trade-offs

  • Tip compatibility must be verified prior to use: The pipette requires confirmation of compatible tip models; improper tip fit can compromise accuracy, precision, and seal integrity, necessitating pre-purchase tip validation.
  • User must manage calibration planning and execution: The calibration reference to ISO 8655-2 indicates that the laboratory is responsible for scheduling and performing periodic recalibration to maintain specified systematic and random error limits.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).