Description
HiPette 12-channel 10-100 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette must be calibrated according to ISO 8655-2 at specified test volumes to maintain accuracy. Sterilization requires full autoclave cycle compatibility with correct tip attachment to prevent damage.
- Calibration Protocol: Systematic and random error must be verified at the test volumes listed in the technical table using a gravimetric method.
- Sterilization Procedure: The pipette is fully autoclavable, but only when disassembled and placed in a sterilization pouch to avoid moisture damage.
- Tip Compatibility: Only tips certified for 10-100 µL multichannel pipettes should be used to ensure proper sealing and accuracy.
This guide covers initial setup, calibration verification, and sterilization procedures for the 12-channel pipette. Follow these steps to ensure accurate liquid handling and equipment longevity.
Required Equipment: HiPette 12-channel pipette
- Volume Adjustment
Set the volume to the desired value by rotating the adjustment knob until the digital display shows the target volume. - Tip Attachment
Attach compatible pipette tips to all 12 channels by pressing firmly until a secure seal is achieved. - Calibration Verification
Verify calibration accuracy at the intended test volume using a gravimetric method per ISO 8655-2. - Sterilization
Sterilize the pipette by autoclaving according to the manufacturer's recommended cycle if sterile conditions are required.
What performance specifications are provided for the HiPette 12-channel 10-100 µL pipette at each test volume?
The technical specifications list systematic error and random error values for the 100 µL, 50 µL, and 10 µL test volumes. These values are retained in the technical table for the multichannel adjustable pipette, and the pipette is calibrated to ISO 8655-2 for traceable accuracy.
What laboratory workflows are the HiPette 12-channel pipette optimized for, and what is the recommended tip type?
The pipette is optimized for microplate loading, PCR plate preparation, ELISA workflows, and parallel reagent transfer. It requires compatible tips for the 10-100 µL range; users should verify tip compatibility for their specific plate format (e.g., 96-well plates) to ensure proper fit and sealing.
How should the HiPette 12-channel pipette be sterilized, and what are the considerations for calibration after autoclaving?
The pipette is fully autoclavable for sterilization. After autoclaving, the pipette should be dried and recalibrated as needed, following the ISO 8655-2 user calibration reference provided in the technical table, to maintain specified accuracy.
The HiPette 12-channel 10-100 µL pipette offers a fully autoclavable, multichannel platform for high-throughput liquid handling in microplate and PCR workflows, but its fixed volume range and dependence on proper tip calibration represent operational constraints.
Positive
- 12-channel parallel liquid handling: Enables simultaneous transfer of 12 samples, significantly accelerating microplate loading, PCR plate preparation, and ELISA workflows compared to single-channel pipettes.
- Fully autoclavable design: Allows complete sterilization of the pipette between uses, reducing cross-contamination risk in microbial and molecular biology applications.
Trade-offs
- Volume range limited to 10–100 µL: Restricted to mid-range microliter volumes; not suitable for sub-10 µL or above-100 µL applications without a separate pipette.
- Requires validated tip and calibration management: Optimal accuracy and precision depend on using compatible tips and routine calibration per ISO 8655-2, adding workflow preparation and verification steps.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).