HiPette 12-Channel Manual Pipette 10-100 μL ATOMFAIR®

$365.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette 12-channel manual pipette for 10-100 μL liquid handling, with 0.1 μL increments and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-F100-12CH
Category: ,
Tags:
Brands:

Description

HiPette 12-channel 10-100 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette 12-channel 10-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10-100 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 10-100 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 10-100 µL with 0.1 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-12CHANNEL-10-100-µL
Product Family HiPette
Channel count 12-channel
Volume range 10-100 µL
Increment 0.1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette must be calibrated according to ISO 8655-2 at specified test volumes to maintain accuracy. Sterilization requires full autoclave cycle compatibility with correct tip attachment to prevent damage.

  • Calibration Protocol: Systematic and random error must be verified at the test volumes listed in the technical table using a gravimetric method.
  • Sterilization Procedure: The pipette is fully autoclavable, but only when disassembled and placed in a sterilization pouch to avoid moisture damage.
  • Tip Compatibility: Only tips certified for 10-100 µL multichannel pipettes should be used to ensure proper sealing and accuracy.

This guide covers initial setup, calibration verification, and sterilization procedures for the 12-channel pipette. Follow these steps to ensure accurate liquid handling and equipment longevity.

Required Equipment: HiPette 12-channel pipette

  1. Volume Adjustment
    Set the volume to the desired value by rotating the adjustment knob until the digital display shows the target volume.
  2. Tip Attachment
    Attach compatible pipette tips to all 12 channels by pressing firmly until a secure seal is achieved.
  3. Calibration Verification
    Verify calibration accuracy at the intended test volume using a gravimetric method per ISO 8655-2.
  4. Sterilization
    Sterilize the pipette by autoclaving according to the manufacturer's recommended cycle if sterile conditions are required.

What performance specifications are provided for the HiPette 12-channel 10-100 µL pipette at each test volume?

The technical specifications list systematic error and random error values for the 100 µL, 50 µL, and 10 µL test volumes. These values are retained in the technical table for the multichannel adjustable pipette, and the pipette is calibrated to ISO 8655-2 for traceable accuracy.

What laboratory workflows are the HiPette 12-channel pipette optimized for, and what is the recommended tip type?

The pipette is optimized for microplate loading, PCR plate preparation, ELISA workflows, and parallel reagent transfer. It requires compatible tips for the 10-100 µL range; users should verify tip compatibility for their specific plate format (e.g., 96-well plates) to ensure proper fit and sealing.

How should the HiPette 12-channel pipette be sterilized, and what are the considerations for calibration after autoclaving?

The pipette is fully autoclavable for sterilization. After autoclaving, the pipette should be dried and recalibrated as needed, following the ISO 8655-2 user calibration reference provided in the technical table, to maintain specified accuracy.

The HiPette 12-channel 10-100 µL pipette offers a fully autoclavable, multichannel platform for high-throughput liquid handling in microplate and PCR workflows, but its fixed volume range and dependence on proper tip calibration represent operational constraints.

Positive

  • 12-channel parallel liquid handling: Enables simultaneous transfer of 12 samples, significantly accelerating microplate loading, PCR plate preparation, and ELISA workflows compared to single-channel pipettes.
  • Fully autoclavable design: Allows complete sterilization of the pipette between uses, reducing cross-contamination risk in microbial and molecular biology applications.

Trade-offs

  • Volume range limited to 10–100 µL: Restricted to mid-range microliter volumes; not suitable for sub-10 µL or above-100 µL applications without a separate pipette.
  • Requires validated tip and calibration management: Optimal accuracy and precision depend on using compatible tips and routine calibration per ISO 8655-2, adding workflow preparation and verification steps.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).