FTIR 835 Portable Spectrometer 2 cm-1 Resolution ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Portable FTIR spectrometer with 7000-400 cm-1 range, 2 cm-1 resolution, ATR/transmission/reflection sampling, USB, and 12 VDC power for lab or field analysis.

SKU: AFMSUNZC296
Category:
Tags:
Brands:

 

Atomfair FTIR 835 Portable FTIR Spectrometer

Product Overview

Atomfair FTIR 835 Portable Fourier Transform Infrared Spectrometer achieves excellent performance in a compact body with high cost performance and unique design. Its innovative optical structure and exclusive software & hardware configuration greatly shorten the analysis cycle. It is suitable for precise laboratory research, teaching scenarios in universities and colleges, as well as on-site testing in outdoor and remote areas. It is a professional analytical instrument with both versatility and portability.

Core Features

  1. Compact and portable: small body size, easy to carry and move, suitable for a variety of usage scenarios
  2. Optical innovation: adopts a new type of compact pendulum roof mirror optical system, avoiding the traditional corner cube optical design and dynamic calibration requirements, solving the optical alignment problem of traditional optical interferometers
  3. Efficient analysis: matched with specially designed software and firmware, significantly reduce the overall analysis time and improve detection efficiency
  4. Diverse scenarios: meet the needs of various scenarios such as precise laboratory analysis, college teaching practice, outdoor and remote area on-site testing

Technical Specifications (International Standard)

Item Parameter Details
Infrared wavelength range 7000 – 400 cm⁻¹
ZnSe wavelength range 5000 – 600 cm⁻¹
Resolution 2 cm⁻¹
Interferometer type Pendulum type
Standard infrared beam splitter Multi-coated KBr
Optional infrared beam splitter Multi-coated ZnSe
Sample processing method ATR (1 or 3 reflections), Transmission, Reflection
Frequency reference VCSEL Laser
Infrared light source Ceramic
Drying oven configuration Equipped
Interface type USB
Data acquisition system 24-bit, high speed
Power supply specification 12 VDC, 30W
Body size (W × D × H) 49 cm × 39 cm × 20 cm
Weight 12 kg
Working temperature environment 15 – 28℃
Working humidity environment Below 65%

Basic Configuration

Includes exclusive analysis software, adapted to the operation of various instrument functions and data processing requirements.

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

Operate the FTIR 835 within 15-28°C and below 65% humidity to achieve specified performance. The spectrometer must be powered by a 12 VDC supply delivering at least 30W.

  • Environmental Conditions: Maintain ambient temperature between 15-28°C and relative humidity under 65% during operation.
  • Power Requirement: Connect the instrument to a stable 12 VDC power source with a minimum capacity of 30W.

How does the pendulum roof mirror optical system in the Atomfair FTIR 835 improve alignment reliability compared to traditional corner cube interferometers?

The Atomfair FTIR 835 uses a pendulum roof mirror interferometer that inherently maintains optical alignment without the need for dynamic calibration, which is typically required in corner cube designs. This innovation solves the optical alignment problems of traditional interferometers, providing long-term stability and reducing maintenance frequency. The design is described as avoiding traditional corner cube optical design and dynamic calibration requirements.

What environmental conditions must be maintained to operate the Atomfair FTIR 835 reliably in field or laboratory settings?

The Atomfair FTIR 835 is specified for operation within an ambient temperature range of 15–28°C and relative humidity below 65%. Exceeding these limits can affect optical alignment and promote condensation on sensitive components. The instrument includes a built-in drying oven to manage internal moisture, but the surrounding environment must still stay within these parameters for accurate performance.

Which sample handling methods are supported by the Atomfair FTIR 835 and how do the ATR reflection options affect analysis?

The spectrometer supports ATR (with 1 or 3 reflections), transmission, and reflection sampling methods. The ATR option provides convenient surface analysis of solids and liquids without extensive sample preparation; the choice between 1 and 3 reflections influences the path length and hence sensitivity for different sample types. The instrument comes with a standard multi-coated KBr beam splitter and an optional ZnSe beam splitter for different wavelength ranges, allowing adaptation to specific sample chemistries.

The Atomfair FTIR 835 Portable FTIR Spectrometer combines a compact pendulum roof mirror interferometer with a VCSEL laser frequency reference and 24-bit data acquisition, enabling rapid, drift-resistant analysis across 7000-400 cm⁻¹. Its multi-coated KBr beam splitter and ATR/transmission/reflection sampling options support versatile lab and field use, though operation is constrained to 15-28°C and below 65% humidity.

Positive

  • Compact pendulum interferometer: The pendulum roof mirror optical system eliminates traditional corner cube dynamic alignment, reducing optical misalignment and enabling a compact 49×39×20 cm, 12 kg design suitable for field deployment.
  • VCSEL laser frequency reference: The VCSEL laser provides a stable frequency reference, enhancing wavenumber accuracy and reproducibility across the 7000-400 cm⁻¹ range, critical for quantitative analysis.

Trade-offs

  • Narrow operating temperature range: The instrument requires 15-28°C ambient temperature, limiting use in unconditioned outdoor environments without additional climate control.
  • Humidity sensitivity: Operation is restricted to below 65% relative humidity; the built-in drying oven mitigates moisture but does not eliminate the need for humidity management in tropical or coastal settings.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).