dPette-S Single-channel 5-50 µL Pipette

Product Type: Electronic pipette
Research-grade liquid handling platform

Product Overview

dPette-S Single-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 5-50 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 5-50 µL with 0.1 µL increment.
  • Sterilization suitability: Lower half autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-DPETTE-S-5-50-µL
Product Family dPette-S
Channel count Single-channel
Volume range 5-50 µL
Increment 0.1 µL
Test volume(s) 5 µL
Systematic error At 5 µL: ±0.50 µL (±10.00%)
Random error At 5 µL: ±0.75 µL (±15.00%)
Sterilization suitability Lower half autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Electronic pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This document outlines the operational constraints for the dPette-S single-channel electronic pipette. Users must adhere to calibration, sterilization, and tip compatibility requirements to maintain accuracy and equipment integrity.

  • Calibration Requirement: Calibration must be performed according to ISO 8655-2 at the specified test volume of 5 µL to verify systematic and random error tolerances.
  • Sterilization Constraint: Only the lower half of the pipette is autoclavable; the upper electronic section must not be subjected to moist heat or immersion.
  • Tip Compatibility: Only compatible pipette tips meeting the manufacturer's fit specifications should be used to ensure repeatable performance and prevent leakage.
  • Volume Increment Handling: The 0.1 µL increment allows fine adjustment but method-specific volume matching is recommended for optimal accuracy.
  • Pre-Order Workflow Planning: Before ordering, confirm calibration frequency, sterilization protocol, and tip selection for the intended laboratory workflow.

What are the systematic and random errors of the dPette-S 5-50 µL pipette at the 5 µL test volume, and how do these error values affect low-volume pipetting accuracy?

At 5 µL, the systematic error is ±0.50 µL (±10.00%) and the random error is ±0.75 µL (±15.00%), as stated in the technical specifications. These relatively high percentage errors at the low end of the volume range indicate that accuracy and precision degrade significantly at very small volumes, which is typical for manual pipettes; users should consider using a pipette with a lower volume range for better performance when pipetting near 5 µL.

Does the dPette-S 5-50 µL pipette require specific tip brands or is it compatible with universal tips?

The product description does not specify the type or brand of compatible pipette tips. As a single-channel manual pipette in the 5-50 µL range, it is likely to accept standard universal tips designed for 200-300 µL capacity, but users should confirm tip fit, sealing, and release force with Atomfair or test with their preferred tips before routine use to avoid leakage or inaccuracy.

Can the dPette-S pipette be fully autoclaved, or is there a specific sterilization protocol?

Only the lower half of the dPette-S pipette is autoclavable, as stated in the specifications. The upper half, which may contain electronic or mechanical components, should not be autoclaved. Users must follow standard protocol by separating the lower half for steam sterilization and cleaning the upper half with a suitable disinfectant to prevent damage and maintain performance.

The dPette-S single-channel 5-50 µL pipette provides a 0.1 µL increment and autoclavable lower half for routine liquid handling, but its accuracy and precision at the 5 µL test volume are relatively high (±10% systematic, ±15% random), necessitating careful calibration tracking for low-volume workflows.

Positive

  • Single-channel for precise liquid handling: The single-channel configuration is optimized for single-tube sample preparation, reagent addition, serial dilution, PCR/qPCR setup, and routine analytical transfer, ensuring repeatability and stable tip fit.
  • Autoclavable lower half for sterilization: The lower half of the pipette is autoclavable, allowing decontamination between uses to maintain aseptic conditions in research and teaching labs.

Trade-offs

  • High error at low test volume: At the 5 µL test volume, systematic error is ±0.50 µL (±10.00%) and random error is ±0.75 µL (±15.00%), which may limit accuracy for low-volume applications without frequent calibration.
  • Partial autoclavability only: Only the lower half is autoclavable; the upper half cannot be sterilized by autoclaving, requiring alternative sterilization methods for full decontamination.