dPette+ 8-channel 10-100 µL Pipette

Product Type: 8-channel electronic pipette
Research-grade liquid handling platform

Product Overview

dPette+ 8-channel 10-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10-100 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 10-100 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 10-100 µL with 0.1 µL increment.
  • Sterilization suitability: Lower half autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-DPETTE-PLUS-8CHANNEL-10-100-µL
Product Family dPette+
Channel count 8-channel
Volume range 10-100 µL
Increment 0.1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error At 100 µL: ±0.80 µL (±0.80%); at 50 µL: ±0.50 µL (±1.00%); at 10 µL: ±0.30 µL (±3.00%)
Random error At 100 µL: ±0.30 µL (±0.30%); at 50 µL: ±0.40 µL (±0.80%); at 10 µL: ±0.20 µL (±2.00%)
Sterilization suitability Lower half autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note dPette+ multichannel electronic pipette table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy across test volumes. The lower half is autoclavable for sterilization, but the upper assembly must not be autoclaved.

  • Calibration Requirement: User calibration must be performed according to ISO 8655-2 at the three specified test volumes to validate systematic and random error.
  • Sterilization Restriction: Only the lower half of the pipette is autoclavable; do not autoclave the upper half or electronic components.
  • Tip Compatibility: Select tips that are specifically designed for 8-channel pipettes and compatible with the 10-100 µL volume range to ensure proper tip seal and accuracy.

How does the dPette+ 8-channel pipette accuracy vary across the 10-100 µL working range?

Systematic error ranges from ±0.80 µL (±0.80%) at 100 µL to ±0.30 µL (±3.00%) at 10 µL, while random error ranges from ±0.30 µL (±0.30%) at 100 µL to ±0.20 µL (±2.00%) at 10 µL. This indicates that relative error increases significantly at lower volumes, with the highest relative systematic error of 3.00% at 10 µL, making the pipette best suited for mid-to-high volume transfers within its range.

What sterilization and compatibility requirements apply to the dPette+ 8-channel electronic pipette for microplate and PCR workflows?

The lower half of the pipette is autoclavable, enabling sterilization of the tip-holding section between uses. The pipette is calibrated per ISO 8655-2 and is designed for 8-channel parallel transfer in microplate, PCR plate, and ELISA workflows. Compatible tips must be confirmed before ordering, as no specific tip brand is listed in the specifications.

What calibration and maintenance procedures are recommended for the dPette+ 8-channel pipette to ensure consistent performance?

The pipette includes a user calibration reference per ISO 8655-2, with systematic and random error verified at 100 µL, 50 µL, and 10 µL. The lower half can be autoclaved for sterilization, and routine performance review should use the listed test volumes. For method-specific volume matching or calibration planning, Atomfair technical support is available.

The dPette+ 8-channel 10-100 µL pipette is evaluated for its 8-channel parallel liquid handling capability and autoclavable lower half, which support high-throughput microplate and PCR workflows. However, the systematic error of ±3.00% at 10 µL and partial autoclavability (lower half only) introduce operational constraints for low-volume precision and full sterilization requirements.

Positive

  • 8-channel parallel liquid handling: The 8-channel configuration enables simultaneous pipetting for microplate loading, PCR plate preparation, and ELISA workflows, increasing throughput and repeatability in parallel reagent transfer.
  • Autoclavable lower half for sterilization: The lower half of the pipette is autoclavable, allowing decontamination between uses to maintain aseptic conditions in sensitive laboratory procedures.

Trade-offs

  • Elevated systematic error at low volume: At 10 µL, the systematic error is ±0.30 µL (±3.00%), which may reduce accuracy for precise low-volume applications compared to the mid-range performance.
  • Partial autoclavability only: Only the lower half is autoclavable; the upper electronic section cannot be sterilized, requiring careful handling to avoid cross-contamination in aseptic workflows.