dPette+ 8-Channel Pipette 30-300 μL, 1 μL Step ATOMFAIR®

$531.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

dPette+ 8-channel pipette covers 30-300 μL with 1 μL increments, ISO 8655-2 calibration reference, and lower-half autoclavability. Order now.

SKU: AF-EI-L-DPPL-J300-08CH
Category: ,
Tags:
Brands:

Description

dPette+ 8-channel 30-300 µL Pipette

Product Type: 8-channel electronic pipette
Research-grade liquid handling platform

Product Overview

dPette+ 8-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 30-300 µL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 1 µL increment.
  • Sterilization suitability: Lower half autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-DPETTE-PLUS-8CHANNEL-30-300-µL
Product Family dPette+
Channel count 8-channel
Volume range 30-300 µL
Increment 1 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error At 300 µL: ±1.80 µL (±0.60%); at 150 µL: ±1.50 µL (±1.00%); at 30 µL: ±0.90 µL (±3.00%)
Random error At 300 µL: ±0.90 µL (±0.30%); at 150 µL: ±0.75 µL (±0.50%); at 30 µL: ±0.30 µL (±1.00%)
Sterilization suitability Lower half autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note dPette+ multichannel electronic pipette table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The lower half of the pipette is autoclavable for sterilization, but the upper electronic assembly must not be autoclaved. Calibration must be verified against ISO 8655-2 at the specified test volumes to maintain accuracy.

  • Sterilization constraint: Only the lower half of the pipette is autoclavable; the electronic upper assembly must be decontaminated by alternative methods.
  • Calibration requirement: Systematic and random error tolerances are defined at 300, 150, and 30 µL per ISO 8655-2, requiring periodic recalibration to maintain specified performance.

How does the accuracy of the dPette+ 8-channel pipette vary across its 30–300 µL range?

The systematic error increases at lower volumes: at 300 µL it is ±0.60%, at 150 µL ±1.00%, and at 30 µL ±3.00%. Random error also increases: at 300 µL ±0.30%, at 150 µL ±0.50%, and at 30 µL ±1.00%. These values are from the technical specifications table.

What calibration standard does the dPette+ 8-channel pipette follow, and does it require special tips?

The pipette is calibrated per ISO 8655-2, as indicated in the technical table. The configuration support note states that compatible tips, calibration requirements, and sterilization needs must be confirmed before ordering. The pipette is designed for 8-channel microplate loading, PCR, and ELISA workflows, suggesting standard 200 µL or 300 µL tips, but the exact tip model is not specified in the source.

Is the dPette+ 8-channel pipette fully autoclavable for decontamination?

No, only the lower half of the pipette is autoclavable. The sterilization suitability is listed as 'Lower half autoclavable', meaning the upper electronic assembly must not be autoclaved. This is explicitly stated in the technical specifications.

The dPette+ 8-channel 30-300 µL Pipette is an electronic multichannel pipette offering parallel liquid handling for microplate and PCR workflows, with ISO 8655-2 calibration traceability and autoclavable lower half, but with constraints on full sterilization and user calibration requirements.

Positive

  • 8-channel parallel processing: The 8-channel configuration enables simultaneous pipetting for microplate loading, PCR plate preparation, and ELISA workflows, increasing throughput and reproducibility in routine liquid handling.
  • ISO 8655-2 calibration traceability: Systematic and random error values are provided per test volume with reference to ISO 8655-2, allowing users to verify performance and maintain calibration records for method compliance.

Trade-offs

  • Limited sterilization compatibility: Only the lower half of the pipette is autoclavable; the upper assembly cannot be sterilized by autoclaving, requiring alternative disinfection procedures for full sterilization.
  • User calibration required: Calibration is user-adjustable via ISO 8655-2 reference, necessitating access to calibration tools and expertise to maintain specified accuracy over time.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).