Diffraction Light Intensity System DLS 836 ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

DLS 836 measures diffraction light intensity for single-, multi-slit, and circular apertures with a 1.5mW He-Ne laser, 0.01mm accuracy, and 1.2m rail.

SKU: AFMSPZWX011
Category:
Brands:

 

Atomfair DLS 836 Diffraction Light Intensity Experimental System

Product Overview

The Atomfair DLS 836 is a professional experimental device dedicated to interference, diffraction, and polarization studies. Tailored specifically for college general physics experiments, it adopts a high-performance photocell as the core detector, integrating stability, ease of use, intuitive results, and precise readings. Equipped with a complete set of standardized components, this system enables accurate measurement and in-depth analysis of diffraction light intensity, making it an ideal tool for physics teaching and experimental research.

Key Features

  • Stable Performance: Boasts reliable operational status, ensuring the smooth progress of experiments without unexpected interruptions.
  • Easy Operation: Simplifies complex experimental procedures, lowering the operational threshold for students and researchers.
  • Intuitive Results: Presents clear and distinguishable experimental phenomena, facilitating easy observation, recording, and analysis.
  • Precise Readings: Delivers highly accurate experimental data, laying a solid foundation for scientific data analysis and conclusion drawing.

Experimental Capabilities

  • Conducts point-by-point measurement of diffraction light intensity for various structures, including Fraunhofer single-slit, multi-slit, and circular aperture.
  • Supports manual drawing of light intensity distribution curves for diffraction patterns, enabling visual analysis of experimental data.

Technical Specifications & Package Contents

No. Product Name Specifications
1 Helium-Neon Laser Power: Approximately 1.5mW, including a matching bracket
2 Optical Rail Length: 1.2m, Material: Hard Aluminum, Straightness: 2mm, Profile Width: 20mm
3 Sliding Base 3 types included: Ordinary type, Horizontal adjustment type, 2D adjustment type
4 Lens 2 focal length options: f’=6.2mm, 150mm
5 Transmission Grating Grating Constant: 201 lines/m, with protective frame
6 Horizontal Movement Measuring Stand Measurement Accuracy: 0.01mm
7 Adjustment Frame Includes lens holder, plate holder, and adjustable slit
8 Multi-hole Plate Material: Chromium Plate
9 Multi-slit Plate 4 slit number options: 2-slit, 3-slit, 4-slit, 5-slit
10 Other Accessories Light target, white screen, optical power tester

Note: The above configurations and parameters are for reference only. Actual specifications are subject to the product packing list. Minor adjustments may be made without prior notice.

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

What measurement precision does the Atomfair DLS 836 provide for diffraction light intensity point-by-point measurements?

The horizontal movement measuring stand offers a measurement accuracy of 0.01 mm, enabling precise positioning for point-by-point diffraction intensity scans. Combined with the high-performance photocell detector, the system delivers stable and accurate readings across the optical rail.

Which diffraction structures can be analyzed with the Atomfair DLS 836 system?

The system supports Fraunhofer diffraction from single-slit, multi-slit (2, 3, 4, and 5 slits via the included multi-slit plate), and circular aperture configurations. A multi-hole plate (chromium plate) is also provided for circular aperture experiments.

What are the key infrastructure requirements for setting up the Atomfair DLS 836 optical rail?

The optical rail is 1.2 m long, made of hard aluminum with a profile width of 20 mm and straightness tolerance of 2 mm. Three types of sliding bases (ordinary, horizontal adjustment, and 2D adjustment) are included to facilitate precise alignment of optical components along the rail.

The Atomfair DLS 836 is a complete optical rail system for undergraduate physics labs, integrating a 1.5mW He-Ne laser, precision translation stage, and multi-slit/circular aperture plates to enable point-by-point Fraunhofer diffraction intensity mapping. Its 0.01mm measurement accuracy and manual curve-plotting workflow support quantitative analysis, though the system requires a dark environment and manual data acquisition.

Positive

  • High-precision translation stage: The horizontal movement measuring stand provides 0.01mm measurement accuracy, enabling precise point-by-point mapping of diffraction intensity distributions for quantitative analysis.
  • Comprehensive accessory set: Includes a 1.5mW He-Ne laser, multiple slit plates (2-5 slits), circular aperture, and two lenses (f'=6.2mm and 150mm), supporting diverse diffraction experiments without additional purchases.

Trade-offs

  • Manual data acquisition required: The system requires manual point-by-point measurement and hand-drawn intensity distribution curves, which is time-consuming and limits throughput for large datasets.
  • Environmental sensitivity to vibration and light: The 1.2m optical rail and sensitive photocell demand a stable, dark environment; ambient light or mechanical vibration can compromise measurement accuracy.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).