|
Laboratory Open-Cell Copper Foam, 20 PPI, 100 × 100 × 10 mm, 1/5 pcs
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For PPI selection, sheet-dimension confirmation, package support or application-specific configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Laboratory open-cell copper foam requires controlled storage and handling to preserve its porous structure. The material must be kept clean and dry and protected from impact, crushing, and contamination.
- Storage Requirement: Store the sheets in a clean, dry area.
- Surface Protection: Protect the open cellular surface from heavy impact, crushing, and contamination.
- Pre-Installation Inspection: Check the package condition, sheet dimensions, and visible pore structure before cutting, bonding, or installing.
- Selection Confirmation: Confirm pore density, pore pitch, porosity, and sheet dimensions before ordering.
This procedure covers the inspection, storage, and preparation of open-cell copper foam sheets before cutting, bonding, or installation. Steps follow the manufacturer's handling and inspection guidance to ensure material integrity.
- Inspect Package
Inspect the package condition upon delivery. - Verify Dimensions
Verify the sheet dimensions against the specification. - Examine Pore Structure
Examine the visible pore structure for consistency. - Store in Clean Dry Area
Store the sheets in a clean, dry area. - Protect Surface
Protect the open cellular surface from heavy impact, crushing, and contamination. - Confirm Integrity Before Processing
Confirm the material integrity before cutting, bonding, or installing.
How does the ≥98% through-pore rate of this 20 PPI copper foam affect its performance in electrode and filtration applications compared to foams with lower through-pore rates?
The ≥98% through-pore rate ensures that nearly all pores are interconnected, maximizing internal surface exposure for electrochemical reactions in electrode frameworks and providing unobstructed fluid pathways for filtration. This high interconnectivity is critical for applications requiring uniform current distribution or consistent flow, as stated in the product's typical applications for nickel-zinc batteries and water purification.
What are the key dimensional and structural parameters to verify before integrating this 100×100×10 mm copper foam sheet into a custom assembly?
Before integration, confirm PPI (20), nominal pore pitch (1.27 mm), porosity (50-80%), through-pore rate (≥98%), sheet dimensions (100×100 mm), thickness (10 mm), and bulk density (0.1-0.8 g/cm³). The selection guidance emphasizes verifying these parameters against application requirements, especially pore geometry and integration method, to ensure compatibility.
What storage and handling conditions are recommended to preserve the open-cell structure of this copper foam sheet during laboratory use?
Store the sheets in a clean, dry area and protect the open cellular surface from heavy impact, crushing, and contamination. After delivery, inspect package condition, sheet dimensions, and visible pore structure before any cutting, bonding, or installation to avoid compromising the interconnected network.
This 20 PPI open-cell copper foam sheet provides a 100×100×10 mm interconnected porous network with ≥98% through-pore rate and tunable porosity (50–80%) and bulk density (0.1–0.8 g/cm³), suitable for electrode, catalyst, thermal, filtration, and shielding applications, but requires careful handling and parametric selection.
Positive
- High through-pore rate: Excellent interconnected open network with ≥98% through-pore rate maximizes internal surface exposure for electrode, catalyst, and filtration applications.
- Adjustable porosity and density: Porosity range of 50–80% and bulk density of 0.1–0.8 g/cm³ allow tuning of thermal/electrical performance for specific engineering needs.
Trade-offs
- Fragile cellular structure: Open-cell foam requires careful handling to avoid crushing or contamination, and must be stored in a clean, dry environment.
- Parametric selection required: Users must confirm PPI, pore pitch, porosity, dimensions, and integration method before ordering, as custom sizing is only available upon consultation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).







