1. Product Overview

Atomfair-VS-826 Visible Spectrophotometer is a cost-effective professional laboratory analytical instrument, equipped with an upgraded optimized optical system and imported core components. It integrates high detection precision, excellent operational stability and easy operation, capable of qualitative identification, quantitative analysis, purity testing and spectral scanning of various substances. Compatible with liquid, solid, powder and other sample forms with excellent photometric linearity, it meets the needs of routine laboratory testing, teaching training, industrial quality inspection and scientific research analysis. Widely used in chemical industry, food, pharmaceutical, environmental water quality monitoring, biomedicine, material testing and other industries, it is an essential high-precision basic analytical equipment for laboratories.

2. Core Features

  1. High-quality optical configuration: Equipped with imported long-life halogen tungsten lamp with stable luminescence, long service life, wide wavelength coverage and high luminous efficiency; standard high-precision holographic diffraction grating with excellent light splitting effect and low stray light to ensure the accuracy of test data from the source.
  2. Excellent detection performance: All core indicators meet international high standards, wavelength accuracy ±2nm, wavelength repeatability ≤1nm, photometric accuracy ±0.5%T, photometric repeatability ≤0.2%T, stray light ≤0.5%T, meeting the accurate testing needs of various routine samples.
  3. Wide measuring range & high adaptability: Full coverage of photometric measurement range 0-200%T (Transmittance), 0-2.0Abs (Absorbance), 0-9999C (Concentration), supporting direct concentration reading and standard curve fitting function. Adapt to samples with different concentration gradients without repeated dilution, efficient and worry-free testing.
  4. Humanized & convenient design: Equipped with high-definition LCD screen, supporting bilingual operation interface (Chinese & English), concise and easy-to-understand menu with one-key operation logic, quick to master without professional training; large-capacity sample chamber compatible with 10mm, 20mm, 50mm cuvettes of all specifications for multi-type sample testing; no complex mechanical transmission structure, anti-seismic, anti-interference, silent operation, suitable for complex laboratory environment.
  5. Complete practical test functions: Support photometric measurement, quantitative analysis, spectral scanning, simultaneous multi-wavelength testing, automatic peak & valley detection, as well as data storage, printing and export; built-in standard working curves for direct use, support multi-group data comparison and analysis, greatly improving daily testing efficiency.
  6. Stable, durable & easy maintenance: Sealed dust-proof and moisture-proof design for optical core components, effectively isolating dust and moisture erosion to extend instrument service life; modular independent installation of tungsten lamp for easy replacement without professional debugging; low power consumption, fast heat dissipation, stable data without drift during long-term continuous operation with low maintenance cost.
  7. Cost-effective & flexible expansion: Optional accessories including solid sample holder, special cuvette rack, thermal printer, data export U disk can be selected on demand, taking into account basic testing and advanced experimental needs, adapting to customized application scenarios in different industries with outstanding cost performance.

3. Specification Parameters

Item Detailed Parameters
Wavelength Range 320-1100nm
Spectral Bandwidth 4nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ≤1nm
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Stray Light ≤0.5%T (440nm NaNO₂)
Photometric Measuring Range Transmittance: 0-200%T; Absorbance: 0-2.0Abs; Concentration: 0-9999C
Baseline Flatness ±0.003Abs
Photometric Drift ≤0.001Abs/h (500nm, after warm-up)
Detector Imported high-performance silicon photodiode
Light Source Imported long-life halogen tungsten lamp
Dispersion Element High-precision holographic diffraction grating
Display System High-definition LCD screen (Chinese & English bilingual interface)
Sample Chamber Large capacity, compatible with 10/20/50mm standard cuvettes
Core Test Functions Photometric measurement, Quantitative analysis, Spectral scanning, Multi-wavelength measurement, Automatic peak & valley detection
Data Output USB interface, Data printing, U disk export
Power Supply AC 220V±10%, 50/60Hz
Machine Features No mechanical transmission structure, anti-seismic, anti-interference, silent operation, low power consumption, fast heat dissipation

4. Typical Applications

  • Chemical industry: Purity detection of chemical raw materials, qualitative & quantitative analysis of organic/inorganic compounds, intermediate content determination, pigment and dye concentration testing
  • Food industry: Detection of food additives/preservatives/pigment content, quantitative analysis of sugar and vitamins in beverages, food color and purity identification
  • Pharmaceutical industry: Active ingredient content detection of proprietary Chinese medicines, raw material impurity screening, pharmaceutical excipient purity analysis, oral liquid concentration calibration
  • Environmental protection: Routine water quality monitoring (turbidity, chroma, ammonia nitrogen, nitrate content), sewage pollutant concentration analysis, drinking water safety testing
  • Biomedicine: Biochemical reagent concentration determination, serum sample routine testing, enzyme activity qualitative analysis, plant extract content testing
  • Material industry: Color and purity detection of coatings/plastics/rubber, textile dye concentration analysis, visible light characteristic testing of nanomaterials
  • Teaching & Scientific Research: Physics and chemistry experiment training in universities, routine sample qualitative identification in research institutes, introductory spectral analysis teaching in laboratories

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.

 

This instrument requires a stable power supply of AC 220V±10% and a vibration-free benchtop to maintain specified wavelength and photometric accuracy. Optical components are sealed against dust and moisture, but the instrument should be operated in a clean laboratory environment to prevent long-term drift.

  • Warm-up Requirement: Allow the instrument to stabilize after power-on to achieve photometric drift ≤0.001Abs/h.
  • Cuvette Compatibility: Use standard 10 mm, 20 mm, or 50 mm cuvettes in the sample chamber for all measurements.
  • Environmental Sensitivity: Sealed optical design minimizes dust and moisture ingress, but avoid extreme temperature or humidity variations to preserve baseline flatness.

What is the photometric drift stability of the Atomfair-VS-826 for long-term kinetic measurements?

The Atomfair-VS-826 exhibits a photometric drift of ≤0.001 Abs/h at 500 nm after a warm-up period, ensuring stable data for extended kinetic runs. Combined with a baseline flatness of ±0.003 Abs and low stray light (≤0.5%T at 440 nm NaNO₂), this instrument maintains high precision over time without signal drift.

Can the Atomfair-VS-826 accommodate non-standard cuvette sizes or solid samples without additional accessories?

The large-capacity sample chamber is directly compatible with 10 mm, 20 mm, and 50 mm standard cuvettes, but for solid samples or non-standard cell dimensions, an optional solid sample holder and special cuvette rack are required. The instrument does not include these in the base configuration and they must be purchased separately.

What are the power and environmental requirements for operating the Atomfair-VS-826 in a laboratory?

The spectrophotometer requires an AC power supply of 220 V ±10% at 50/60 Hz. Its sealed dust-proof and moisture-proof optical housing protects core components in humid or dusty environments, and the absence of a mechanical transmission structure makes it resistant to vibration and interference, allowing stable operation on standard benchtops without special isolation.

The Atomfair-VS-826 Visible Spectrophotometer delivers a 320-1100nm wavelength range with a 4nm spectral bandwidth, achieving ±2nm wavelength accuracy and ≤0.5%T stray light, making it suitable for routine quantitative and qualitative analysis across chemical, pharmaceutical, and environmental labs. Its large sample chamber and multi-function software support photometric, quantitative, and spectral scanning modes, though the AC 220V power requirement and halogen lamp warm-up drift of ≤0.001Abs/h impose operational constraints.

Positive

  • High optical precision and low stray light: With wavelength accuracy ±2nm, repeatability ≤1nm, and stray light ≤0.5%T at 440nm, the instrument ensures reliable photometric data for routine analysis, supported by a holographic diffraction grating and silicon photodiode detector.
  • Versatile sample handling and measurement modes: The large sample chamber accepts 10/20/50mm cuvettes, and the instrument supports photometric, quantitative, spectral scanning, multi-wavelength, and peak-valley detection functions, enabling direct concentration reading and standard curve fitting without repeated dilution.

Trade-offs

  • Requires stable AC 220V power supply: The instrument operates on AC 220V±10%, 50/60Hz, so laboratories with non-220V mains or unstable voltage will need a voltage regulator or converter, adding infrastructure requirements.
  • Photometric drift after warm-up: Specified drift is ≤0.001Abs/h at 500nm after warm-up, meaning the instrument must be powered on and stabilized before precise measurements, which may slow workflow in high-throughput labs.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).