Single-Chamber High-Pressure Electrochemical CellProduct Type: High-pressure electrochemical cell
Research-grade laboratory product
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, technical compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC LLC
Brand: ATOMFAIR®
|
This high-pressure electrochemical cell is rated for a maximum operating pressure of 6 MPa and requires separately purchased electrodes for operation. All electrode and window selections must be compatible with the experimental conditions and the titanium and stainless steel cell materials.
- Pressure Limit: The maximum allowable operating pressure is 6 MPa to prevent mechanical failure.
- Separate Electrodes: Reference, counter, and working electrodes with appropriate clamps are not included and must be procured separately.
- Material Compatibility: The titanium body and stainless steel valve are compatible with most common electrolyte systems but may require verification for highly aggressive media.
- Customization: Non-standard electrode sizes or window materials require prior specification to ensure proper sealing and performance.
The cell must be assembled with properly selected electrodes and sealed before pressurization. Operate only within the rated pressure limit and use appropriate pressure relief measures.
Required Equipment: Electrode clamp
- Select electrodes and clamp
Select and procure the required reference, counter, and working electrodes along with the electrode clamp. - Inspect cell components
Inspect the titanium cell body and stainless steel valve for any cracks or debris before assembly. - Assemble the cell
Assemble the cell by inserting the electrodes and securing the clamp, ensuring a gas-tight seal. - Pressurize the cell
Slowly pressurize the cell with the experimental gas or electrolyte to the desired level, not exceeding 6 MPa. - Monitor during operation
Monitor the pressure continuously during operation and depressurize immediately if any leakage is detected.
Does the AF-HP-SC single-chamber high-pressure electrochemical cell support both 50 mL and 100 mL volumes at the maximum 6 MPa pressure?
Yes, the specifications list both 50 mL and 100 mL volumes with a maximum operating pressure of 6 MPa. The cell body is constructed from titanium to withstand this pressure, and the valve is stainless steel 304. No variation in pressure rating with volume is indicated.
What electrodes are required to operate the AF-HP-SC cell, and are they included?
The base cell does not include electrodes. The recommended reference electrode is Ag/AgCl, the counter electrode is a platinum sheet, and the working electrode clamp is for a glassy carbon electrode. All are purchased separately. Custom electrode sizes can be accommodated upon inquiry.
What is the valve material on the AF-HP-SC high-pressure electrochemical cell, and why is it significant?
The valve is made of stainless steel 304, as stated in the technical specifications. This material provides corrosion resistance and mechanical strength suitable for high-pressure electrochemical environments. The cell body is titanium, and both materials contribute to the rated 6 MPa maximum pressure.
The Atomfair AF-HP-SC single-chamber high-pressure electrochemical cell provides a titanium body rated to 6 MPa with customizable volume options (50/100 mL), but requires separate procurement of all electrodes and clamps, adding upfront configuration effort.
Positive
- Titanium body with 6 MPa rating: The titanium construction provides excellent corrosion resistance and mechanical integrity for high-pressure electrochemical experiments up to 6 MPa.
- Customizable volume and components: Available in 50 and 100 mL volumes with support for non-standard electrode sizes and window materials, enabling adaptation to specific experimental requirements.
Trade-offs
- Electrodes and clamp sold separately: Reference, counter, and working electrodes along with the electrode clamp must be purchased separately, requiring additional sourcing and compatibility verification.
- Pressure limit of 6 MPa: The maximum operating pressure of 6 MPa may be insufficient for studies requiring higher pressures; the stainless steel 304 valve material may also limit compatibility with aggressive electrolytes.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).