2H Double-Layer Electrolytic Cell 30-250mL ATOMFAIR®

Price range: $440.00 through $629.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

ATOMFAIR® 2H double-layer electrolytic cell, absolute-sealing, for 30-250mL builds. Membrane-separated, vacuum-rated to -100kPa and 0.5MPa.

2H Replaceable-Membrane Electrolytic Cell, Absolute Sealing, Double-Layer | ATOMFAIR

Product Type: Electrochemical cell
Research-grade laboratory product

Product Overview

The ATOMFAIR® Double-Layer Absolute Sealing 2H Replaceable-Membrane Electrolytic Cell is constructed from high-borosilicate glass and designed as an absolutely sealed, two-compartment system for three-electrode applications. The cathode and anode chambers are isolated by an ion-exchange membrane, with chain-sealed connections facilitating easy membrane replacement. The working electrode and reference electrode are positioned in the same compartment to effectively reduce uncompensated resistance (iR drop). Electrode connections are achieved via built-in jacks on the lid, enabling complete internal electrode integration and absolute sealing. The glass sealing features an external threaded port with a 360° rotatable PTFE inner core for precise electrode alignment, secured by a POM outer cap. The cell includes a sub-surface sparger for gas purging (straight type for CO reduction, L-type for nitrogen reduction). Valves enable vacuum capability (below -100kPa) and mild pressurization (up to 0.5MPa). The single-layer body features an elevated floor design that effectively eliminates solution film effects. The double-layer version incorporates a thermostatic water bath jacket for precise temperature control. Electrodes must be custom-ordered as matched sets with this cell model. A sampling port is available as an optional add-on.

Performance Features

  • Absolutely sealed design: Internal electrode jacks on the lid provide complete sealing integrity, ideal for oxygen- and moisture-sensitive experiments.
  • Two-compartment membrane separation: Isolates cathode and anode compartments with ion-exchange membrane for selective ion transport studies.
  • Chain-sealed membrane connections: Facilitates quick and convenient membrane replacement without compromising seal integrity.
  • Co-located working and reference electrodes: Minimizes uncompensated resistance (iR drop) for more accurate electrochemical measurements.
  • 360° rotatable PTFE core design: Allows precise electrode alignment and positioning within the cell.
  • Integrated water bath jacket: Double-layer configuration enables precise thermal regulation for temperature-dependent electrochemical studies.

Technical Specifications

Parameter Specification / Available Values
Product Family 2H Replaceable-Membrane Electrolytic Cell, Absolute Sealing, Double-Layer
Atomfair Model AF-C007-030-590
 Configuration 30ml
Atomfair Model AF-C007-050-C13
 Configuration 50ml
Atomfair Model AF-C007-100-A7E
 Configuration 100ml
Atomfair Model AF-C007-150-2C4
Configuration 150ml
Atomfair Model AF-C007-200-774
Configuration 200ml
Atomfair Model AF-C007-250-FBA
Configuration 250ml
APPLICATION SCOPE: Strictly anaerobic membrane-based electrochemistry, CO reduction, nitrogen reduction, vacuum electrochemical studies, pressurized electrochemical testing (≤0.5MPa), fuel cell research, electrosynthesis, and air-sensitive materials characterization requiring compartment isolation and temperature control.
PACKAGING: Individual shock-proof packaging with specialized foam lining and reinforced cartons to ensure the glass body remains intact during transportation.
IMPORTANT NOTICE: Electrodes must be custom-matched with this cell. Valves not included. Verify seal integrity before vacuum/pressure operation. Do not exceed 0.5MPa. Verify membrane compatibility before use.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Manufacturer: Atomfair LLC

Brand: ATOMFAIR®

This cell requires absolute sealing integrity for anaerobic electrochemistry and must not exceed 0.5 MPa internal pressure. Electrodes must be custom-matched to this cell model, and membrane compatibility must be verified before use.

  • Pressure and Vacuum Limits: The cell supports vacuum below -100 kPa and mild pressurization up to 0.5 MPa, but seal integrity must be verified before each operation.
  • Membrane Compatibility: Only ion-exchange membranes compatible with the experimental chemistry and cell sealing mechanism should be installed.
  • Electrode Matching: Working and reference electrodes must be custom-ordered as matched sets for this specific cell model to ensure proper alignment and sealing.
  • Temperature Control: The double-layer water jacket enables precise thermal regulation, but the circulating fluid must be compatible with the glass and PTFE components.
  • Anaerobic Operation: The absolutely sealed design with internal electrode jacks is required for oxygen- and moisture-sensitive experiments, and all ports must be properly sealed.

Assemble the cell by installing the ion-exchange membrane and custom-matched electrodes, then achieve absolute sealing for vacuum or pressurized operation. Purge the cell with inert gas and verify seal integrity before applying vacuum or pressure up to 0.5 MPa.

Required Equipment: Ion-exchange membrane, Custom-matched electrodes, Vacuum/pressure valves (not included), Inert gas supply

  1. Inspect the cell
    Inspect the glass body and sealing components for cracks or damage before assembly.
  2. Install the membrane
    Install the ion-exchange membrane using the chain-sealed connections to isolate the cathode and anode compartments.
  3. Align and secure electrodes
    Align the working and reference electrodes using the 360° rotatable PTFE core and secure them with the POM outer cap.
  4. Connect the sparger and purge
    Connect the sub-surface sparger and purge the cell with inert gas to remove oxygen and moisture.
  5. Apply vacuum or pressure
    Evacuate the cell to below -100 kPa or pressurize up to 0.5 MPa using the valves, ensuring the seal remains intact.

How does the co-located working and reference electrode design in the ATOMFAIR double-layer cell reduce uncompensated resistance (iR drop) in three-electrode measurements?

The working electrode and reference electrode are positioned in the same compartment to effectively reduce uncompensated resistance (iR drop). This co-location minimizes the solution resistance between the two electrodes, leading to more accurate potential control and measurement in three-electrode experiments. The design is a key feature for high-precision electrochemistry.

What type of electrodes are required for use with this replaceable-membrane electrolytic cell, and how are they integrated?

Electrodes must be custom-ordered as matched sets with this specific cell model. They are integrated via built-in jacks on the lid, which enable complete internal electrode integration and absolute sealing of the cell. The glass sealing employs an external threaded port with a 360° rotatable PTFE inner core secured by a POM outer cap for precise alignment.

What are the maximum operating pressure and vacuum limits for the ATOMFAIR absolute sealing electrolytic cell?

The cell supports vacuum operation below -100 kPa and mild pressurization up to 0.5 MPa. Valves enable these conditions, but seal integrity must be verified before use and the 0.5 MPa limit must not be exceeded. The double-layer version also includes a thermostatic water bath jacket for temperature control during pressurized or vacuum experiments.

The ATOMFAIR Double-Layer Absolute Sealing 2H Replaceable-Membrane Electrolytic Cell offers a robust two-compartment design with chain-sealed membrane connections for easy replacement, and a double-layer water bath jacket for precise thermal control, making it suitable for anaerobic membrane-based electrochemistry and pressurized electrochemical testing up to 0.5 MPa.

Positive

  • Absolute Sealing and Internal Electrode Integration: The lid features built-in electrode jacks allowing complete internal electrode integration, ensuring absolute sealing ideal for oxygen- and moisture-sensitive experiments.
  • Precise Temperature Control via Water Bath Jacket: The double-layer construction integrates a thermostatic water bath jacket, enabling precise thermal regulation for temperature-dependent electrochemical studies.

Trade-offs

  • Electrode Compatibility and Custom Ordering Required: Electrodes are not included and must be custom-ordered as matched sets specifically for this cell model, adding lead time and procurement complexity.
  • Operational Constraints for Vacuum and Pressure: The cell supports vacuum below -100kPa and mild pressurization up to 0.5MPa, but seal integrity must be verified before each operation, and valves are not included.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Capacity / Size

30mL, 50mL, 100mL, 150mL, 200mL, 250mL

Related Products