Carbon Steel Working Electrode 2–5mm Detachable ATOMFAIR®

$60.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade detachable carbon steel working electrode with 2–5mm disk options, 9mm head, PTFE/PEEK body, and 1.5×15mm gold-plated copper rod. Order now.

Brands:

Detachable Electron Microscopy Carbon Steel Working Electrode Series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Detachable Electron Microscopy Carbon Steel Working Electrode features a user-replaceable head design specifically optimized for electrochemical experiments requiring carbon steel substrates for industrial corrosion and cathodic protection studies. The electrode offers a comprehensive range of embedded disk diameters from 2mm to 5mm. The detachable head features a 9mm thickness, while the electrode body is manufactured from premium PTFE or PEEK, providing excellent chemical resistance and mechanical stability. A gold-plated copper rod (1.5×15mm) serves as the conductive medium, ensuring low contact resistance and superior corrosion protection. This design enables convenient electrode surface renewal and maintenance without replacing the entire electrode body, making it particularly suitable for studies simulating industrial environments where electrode material authenticity is critical.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Detachable cylindrical configuration
Rod Length 6mm
Detachable Head Thickness 9mm
Conductive Medium Gold-plated copper rod (1.5 x 15mm)
Insulative Body Material PTFE or PEEK
2. Electrode Material Portfolio Parameters
Material Carbon Steel
Diameter Options 2~5mm

Key Features & Advantages

  • Detachable Head Design: Allows easy replacement or regeneration of the electrode surface, significantly extending the service life of the electrode body and ensuring optimal performance in microscopy-coupled experiments.Specialized Isotropic Carbon Graphite Material:

  • Specialized Carbon Steel Material: Constructed from high-grade carbon steel, providing specific electrochemical characteristics suitable for corrosion studies, materials research, and targeted redox systems.

  • Robust Corrosion Protection: Gold-plated copper rod (1.5x15mm) delivers enhanced oxidation resistance and maintains stable conductivity over extended use.

  • Flexible Diameter Selection: Available in 2mm to 5mm diameter range, accommodating various experimental requirements and allowing researchers to select the optimal size for their specific application.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This product is highly sensitive to surface contamination. Storage and handling must occur in sealed containers within an anhydrous inert environment to prevent degradation.

  • Surface Contamination Sensitivity: Surface contamination can degrade electrochemical performance and must be avoided.
  • Inert Environment Requirement: Handling must be performed exclusively within an anhydrous inert environment to prevent phase contamination.

These steps describe how to prepare the electrode for use while avoiding contamination. The electrode must be handled in an inert environment to maintain performance.

  1. Inspect
    Inspect the electrode surface for visible contamination or damage before use.
  2. Transfer
    Transfer the electrode to an anhydrous inert environment for all subsequent handling.
  3. Assemble
    Attach the detachable head to the electrode body, ensuring a secure fit.

What are the key performance trade-offs of using a detachable carbon steel working electrode compared to a fixed disk electrode in corrosion studies?

The detachable head design enables electrode surface renewal without replacing the entire PTFE or PEEK body, extending service life for long-term corrosion and cathodic protection studies. However, the 9mm fixed head thickness and 6mm rod length may limit cell geometry flexibility compared to solid disk electrodes. The carbon steel substrate provides authentic industrial corrosion behavior, while the gold-plated copper rod (1.5×15mm) ensures low contact resistance and oxidation resistance.

Can this carbon steel working electrode be directly integrated into an SEM or other microscopy-coupled electrochemical cell without additional modifications?

The electrode is designed for microscopy-coupled experiments, with a detachable cylindrical geometry and insulative PTFE or PEEK body materials compatible with vacuum environments. The gold-plated copper rod (1.5×15mm) provides reliable electrical contact. However, the carbon steel surface is highly sensitive to contamination and must be handled exclusively within an anhydrous inert environment or kept tightly sealed to prevent phase contamination before electrochemical validation, which may necessitate specialized sample transfer chambers for ex situ microscopy.

What storage and handling precautions are required to maintain the integrity of the carbon steel working electrode before electrochemical use?

The electrode is shipped in secure research-grade protective containers with shock absorption. To prevent surface contamination, containers must be kept tightly sealed or the electrode handled exclusively within an anhydrous inert environment before electrochemical validation. The gold-plated copper rod provides corrosion protection, but the carbon steel active surface requires careful preparation; the detachable head design facilitates surface renewal without replacing the entire electrode body.

The Atomfair Detachable Electron Microscopy Carbon Steel Working Electrode provides a user-replaceable head design for corrosion and cathodic protection studies, featuring a gold-plated copper rod for stable conductivity, but requires strict anhydrous inert environment handling to prevent surface contamination.

Positive

  • Detachable head for easy surface renewal: The user-replaceable head design allows electrode surface regeneration without replacing the entire body, significantly extending service life for repeated electrochemical experiments.
  • Gold-plated copper rod ensures low contact resistance: The 1.5x15mm gold-plated copper conductive rod provides enhanced oxidation resistance and stable electrical contact, maintaining reliable conductivity over extended use.

Trade-offs

  • High sensitivity to surface contamination: The electrode surface is highly sensitive to contaminants; it must be stored in sealed containers and handled exclusively within an anhydrous inert environment to prevent degradation before use.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).