Aluminum Working Electrode 3mm PTFE-Sealed ATOMFAIR®

$44.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 3mm aluminum working electrode with 5mm head, PTFE leak-proof encapsulation, and 1–10mm custom diameter options for RDE cells. Order now.

SKU: AF-EC-E-ALUM-SPEC-3MM3
Category:
Tags:
Brands:

Standard Aluminum Working Electrode Series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Standard Aluminum Working Electrode delivers exceptional cell-to-cell consistency and eliminates baseline variability for advanced electrochemical systems. Designed for researchers requiring aluminum-based electrode materials for electrochemical studies, this electrode platform provides reliable performance for corrosion research, materials characterization, and specific redox systems. Its universal design fits seamlessly into standard three-electrode cells and rotating disk electrode setups. Featuring a 1mm to 10mm diameter aluminum disk configuration, this working electrode offers a specialized solution for electrochemical applications where aluminum’s lightweight nature, good electrical conductivity, and unique electrochemical behavior in aqueous and non-aqueous systems are required.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Straight / Cylindrical geometry
Encapsulation Material High-grade PTFE (PEEK optional) – Absolute leak-proof sealing, non-contaminating
Electrode Head Length 5mm (Standard production specification)
2. Electrode Material Portfolio Parameters
Material Aluminum
Diameter Options 3mm (standard), 1-10mm (customized)

Key Features & Advantages

  • Specialized Aluminum Material: Constructed from high-purity aluminum, offering excellent electrical conductivity, low density, and specific electrochemical characteristics suitable for corrosion studies, battery research, light-alloy materials characterization, and targeted redox systems.

  • PTFE Leak-Proof Encapsulation: Advanced PTFE jacket ensures absolutely no electrolyte seepage, maintaining baseline stability and protecting the electrode seal during long-term experiments.

  • Flexible Diameter Selection: Available in different sizes from 1mm to 10mm, accommodating various experimental requirements from micro-electrolysis to bulk solution analysis, with the 3mm option being the most commonly used size.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode is highly sensitive to surface contamination and requires storage in sealed containers under an anhydrous inert atmosphere. Phase contamination and degradation can occur if the electrode is exposed to ambient conditions before electrochemical validation.

  • Surface Contamination Sensitivity: The electrode surface is highly sensitive to contamination and must be kept sealed until use.
  • Storage Environment: Containers must be tightly sealed and stored in an anhydrous inert atmosphere to prevent phase contamination.
  • Handling Protocol: Exclusive handling within an anhydrous inert environment is required before electrochemical validation to prevent degradation.

How does the choice of aluminum disk diameter affect electrochemical performance in corrosion studies?

Diameter selection directly affects the electrode's active surface area and current magnitude. The 3mm diameter is standard and most commonly used for general studies, while diameters from 1mm to 10mm are available for customized requirements such as micro-electrolysis (smaller) or bulk solution analysis (larger). The high-purity aluminum material provides excellent electrical conductivity and specific electrochemical characteristics suitable for corrosion research and battery studies.

Is the Standard Aluminum Working Electrode compatible with non-aqueous electrolytes for battery research?

Yes, the aluminum electrode is designed for both aqueous and non-aqueous systems, as indicated in its application scope for advanced energy systems and battery research. The high-grade PTFE encapsulation provides leak-proof sealing and is non-contaminating, ensuring compatibility with sensitive non-aqueous electrolytes. However, the product notice warns that the electrode is highly sensitive to surface contamination if exposed to atmosphere, so proper inert environment handling is required.

What are the required storage and handling conditions to maintain electrode surface integrity?

The electrode must be stored in its secure protective container with shock-absorption parameters. The important notice states that the product is highly sensitive to surface contamination; containers must be kept tightly sealed or handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation. No specific temperature or humidity range is provided, but inert gas glovebox handling is implied.

The ATOMFAIR Standard Aluminum Working Electrode (3mm, SKU AF-EC-E-ALUM-SPEC-3MM3) provides high-purity aluminum with PTFE leak-proof encapsulation for stable baseline performance in corrosion and battery research, but its surface sensitivity demands anhydrous inert handling environments.

Positive

  • PTFE leak-proof encapsulation: The advanced PTFE jacket ensures no electrolyte seepage, maintaining baseline stability and protecting the electrode seal during long-term experiments.
  • Flexible diameter selection: Available in diameters from 1mm to 10mm, the series accommodates various experimental scales from micro-electrolysis to bulk analysis, with the 3mm size as the standard option.

Trade-offs

  • Surface contamination sensitivity: The aluminum electrode is highly sensitive to surface contamination; it must be stored in sealed containers or handled exclusively in an anhydrous inert environment to prevent degradation before use.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).