Vacuum Release Tray 400 Grid Medium Adhesion ATOMFAIR®

$75.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

400-grid, 20×20 array, medium adhesion, ESD-safe vacuum release tray for non-destructive sample detachment in cleanroom workflows. 5pcs. Order now.

SKU: AF-EI-A-LVRT-400M-CB00-PARENT
Category:
Brands:

LID-TYPE VACUUM RELEASE TRAY 400 GRID MEDIUM ADHESION,5pcs

RESEARCH GRADE MATERIAL

Product Overview

The atomfair lid-type vacuum release tray is specifically engineered for critical research environments demanding high-purity, contamination-free, and cross-contamination-proof sample containment alongside meticulous microscopic particulate regulation. This specific configuration features a precision-molded 20×20 Grid Array matrix combined with an advanced Medium surface energy adhesive platform. It is custom-designed to prevent micro-shifting or structural dislodgement during rigorous transport, while simultaneously eliminating microscopic surface residue, adhesive transfer, or localized stress marks upon sample detachment. This non-destructive preservation platform is critical for advanced materials processing, quantum device fabrication, and delicate structural analysis across national frameworks and multi-disciplinary university core labs.

Technical Specifications

PARAMETER DETAILS
1. Core Specification Profile
Grid Configuration 400 Grid (20×20 Array, 1.52×1.44 mm Compartments)
Adhesion Level Medium Adhesion
2. Material Configurations & Ordering Codes
Model: AF-VRB-400M-CB ESD-safe full-black lid + conductive black tray + black insert
Model: AF-VRB-400M-CC Conductive full-black lid + conductive black tray + black insert
Model: AF-VRB-400M-CT ESD-safe clear lid + conductive black tray + clear insert
3. Mesh Selection Matrix
Default Mesh Specification White 16 Mesh
Available Mesh Densities 16 Mesh / 33 Mesh / 76 Mesh / 103 Mesh / 137 Mesh / 195 Mesh
Available Mesh Color Options Standard White Mesh / Yellow Mesh
Ordering Remark Guide If you need to purchase alternative mesh colors or densities, please explicitly state your specific requirements in the order remarks section during checkout.

Key Features & Advantages

  • Precise 20×20 Matrix Isolation: The orthogonal 400-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging.
  • Medium Residue Surface Energy: Specially structural elastomer allows reliable anchor hold while ensuring micro-level non-destructive sample detachment, preventing thin-film peeling or device deformation.
  • Comprehensive ESD Protection: Integrated anti-static matrices and premium conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions.
  • Vacuum & Structural Integrity: Engineered with premium chemical-resistant components to withstand continuous outgassing and multi-cycle depressurization without dimensional warping.

APPLICATION SCOPE: Highly recommended for quantum optics (qubit chips), materials science (2D films, graphene, nanomaterials), semiconductor R&D (MEMS, bare dies, compound wafers), and specialized biotechnology biosensor microfluidic arrays.
PACKAGING: Contains 5 × atomfair lid-type vacuum release tray (400 Grid / Medium Adhesion), 1 × cleanroom compliance certificate, and shock-absorbent shells. Double-vacuum bag sealed under dry inert nitrogen gas atmosphere to guarantee zero contamination during transport.
IMPORTANT ORDERING NOTICE: The default baseline configuration provided is white 16 mesh. If your project mandates alternative mesh counts (33, 76, 103, 137, or 195) or a yellow mesh configuration, please explicitly state your specific color and density requirements within the order remarks field during checkout confirmation.
SYSTEM REQUIREMENT: To activate the Release Mode for sample removal, this vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This tray requires storage in a dry inert nitrogen atmosphere to prevent contamination and must be used with a compatible vacuum station and pump for sample release. Electrostatic discharge protection is mandatory to preserve sample integrity and prevent damage to the polymer components.

  • Inert Atmosphere Storage: Store the tray under dry inert nitrogen gas to maintain zero contamination and prevent moisture adsorption.
  • Vacuum System Requirement: Activate Release Mode only with a compatible vacuum station and vacuum pump to avoid structural failure or sample damage.
  • ESD-Safe Handling: Handle the tray in an ESD-protected environment to prevent electrostatic discharge that could compromise sensitive samples.
  • Cleanroom Compatibility: Use the tray in a controlled cleanroom environment to preserve the low-residue adhesive surface and avoid particulate contamination.

This procedure describes the safe and non-destructive release of samples from the medium-adhesion grid using a vacuum system. Follow these steps to avoid residue transfer or structural deformation.

Required Equipment: Compatible vacuum station, Vacuum pump, ESD-safe tweezers or handling tool

  1. Place tray in vacuum station
    Place the loaded vacuum release tray into the compatible vacuum station, ensuring proper alignment of the release ports.
  2. Connect vacuum pump
    Connect the vacuum pump to the station's inlet and verify the seal is intact before activating the pump.
  3. Activate release mode
    Engage the release mode on the vacuum station to apply controlled negative pressure and detach samples from the adhesive grid.
  4. Remove released samples
    Using ESD-safe tweezers, gently lift each released sample from its compartment, starting from the edge to avoid distortion.

How does selecting a finer mesh density (e.g., 195 mesh) versus the default 16 mesh affect the balance between particle retention and vacuum flow in the Atomfair 400 Grid vacuum release tray?

The default white 16 mesh provides coarse particle capture with the highest vacuum flow for rapid release cycles. Selecting a finer mesh such as 195 mesh improves retention of sub-micron particulates crucial for quantum or 2D material work but reduces vacuum conductance, potentially requiring a higher-capacity pump. The product supports mesh densities from 16 to 195 mesh, and users must explicitly request alternative mesh in order remarks.

What vacuum station and pump compatibility requirements are needed to operate the Atomfair lid-type vacuum release tray for sample detachment?

The tray activates release mode only when paired with a compatible Vacuum Station and Vacuum Pump system, as specified by the manufacturer. The tray is engineered to withstand continuous outgassing and multi-cycle depressurization without dimensional warping, but optimal performance depends on matching pump flow rate and pressure to the selected mesh density and adhesion level.

What storage and handling conditions are required to preserve the contamination-free integrity of the Atomfair vacuum release tray before first use?

Each tray is double-vacuum bag sealed under dry inert nitrogen gas to guarantee zero contamination during transport. Trays should remain in the original shock-absorbent packaging and cleanroom compliance certificate bag until use. For the ESD-safe and conductive variants, storage on grounded or dissipative surfaces is recommended to maintain electrostatic protection before deployment.

This lid-type vacuum release tray with 400-grid medium adhesion platform is engineered for high-purity sample containment in quantum optics, materials science, and semiconductor R&D, offering precise isolation and non-destructive release but requiring dedicated vacuum system and explicit mesh specification.

Positive

  • Precise Grid Isolation and Non-Destructive Release: The 400-grid (20×20) configuration with medium adhesion platform enables systematic sample mapping and micro-level detachment without residue or stress marks, critical for sensitive materials like 2D films and quantum devices.
  • Integrated ESD Protection and Vacuum Robustness: Anti-static matrices and conductive polymer backings provide dissipative pathways to prevent electrostatic damage, while chemical-resistant components withstand continuous outgassing and multi-cycle depressurization without warping.

Trade-offs

  • Requires Dedicated Vacuum Infrastructure: The vacuum release tray must be used with a compatible vacuum station and vacuum pump to activate the release mode, adding equipment dependency and laboratory setup cost.
  • Mesh Configuration Must Be Specified at Order: Default mesh is white 16 mesh; alternative densities (33-195 mesh) or yellow mesh require explicit order remarks, potentially delaying procurement if not specified.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Specification

ESD-safe full-black lid + conductive black tray + black insert 5pcs, Conductive full-black lid + conductive black tray + black insert 5pcs, ESD-safe clear lid + conductive black tray + clear insert 5pcs