Vacuum Release Tray 100-Grid High Adhesion, ATOMFAIR®

$75.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research grade lid-type vacuum release tray with 10×10 100-grid high-adhesion surface, 3×3 mm compartments, ESD/conductive options, 5 pcs. Order now.

SKU: AF-EI-A-LVRT-100H-CB00-PARENT
Category:
Brands:

LID-TYPE VACUUM RELEASE TRAY 100 GRID HIGH ADHESION,5pcs

RESEARCH GRADE MATERIAL

Product Overview

The atomfair lid-type vacuum release tray is specifically engineered for critical research environments demanding high-purity, contamination-free, and cross-contamination-proof sample containment alongside meticulous microscopic particulate regulation. This specific configuration features a precision-molded 10×10 Grid Array matrix combined with an advanced High surface energy adhesive platform. It is custom-designed to prevent micro-shifting or structural dislodgement during rigorous transport, while simultaneously eliminating microscopic surface residue, adhesive transfer, or localized stress marks upon sample detachment. This non-destructive preservation platform is critical for advanced materials processing, quantum device fabrication, and delicate structural analysis across national frameworks and multi-disciplinary university core labs.

Technical Specifications

PARAMETER DETAILS
1. Core Specification Profile
Grid Configuration 100 Grid (10×10 Array, 3×3 mm Compartments)
Adhesion Level High Adhesion
2. Material Configurations & Ordering Codes
Model: AF-VRB-100H-CB ESD-safe full-black lid + conductive black tray + black insert
Model: AF-VRB-100H-CC Conductive full-black lid + conductive black tray + black insert
Model: AF-VRB-100H-CT ESD-safe clear lid + conductive black tray + clear insert
3. Mesh Selection Matrix
Default Mesh Specification White 16 Mesh
Available Mesh Densities 16 Mesh / 33 Mesh / 76 Mesh / 103 Mesh / 137 Mesh / 195 Mesh
Available Mesh Color Options Standard White Mesh / Yellow Mesh
Ordering Remark Guide If you need to purchase alternative mesh colors or densities, please explicitly state your specific requirements in the order remarks section during checkout.

Key Features & Advantages

  • Precise 10×10 Matrix Isolation: The orthogonal 100-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging.
  • High Residue Surface Energy: Specially structural elastomer allows reliable anchor hold while ensuring micro-level non-destructive sample detachment, preventing thin-film peeling or device deformation.
  • Comprehensive ESD Protection: Integrated anti-static matrices and premium conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions.
  • Vacuum & Structural Integrity: Engineered with premium chemical-resistant components to withstand continuous outgassing and multi-cycle depressurization without dimensional warping.

APPLICATION SCOPE: Highly recommended for quantum optics (qubit chips), materials science (2D films, graphene, nanomaterials), semiconductor R&D (MEMS, bare dies, compound wafers), and specialized biotechnology biosensor microfluidic arrays.
PACKAGING: Contains 5 × atomfair lid-type vacuum release tray (100 Grid / High Adhesion), 1 × cleanroom compliance certificate, and shock-absorbent shells. Double-vacuum bag sealed under dry inert nitrogen gas atmosphere to guarantee zero contamination during transport.
IMPORTANT ORDERING NOTICE: The default baseline configuration provided is white 16 mesh. If your project mandates alternative mesh counts (33, 76, 103, 137, or 195) or a yellow mesh configuration, please explicitly state your specific color and density requirements within the order remarks field during checkout confirmation.
SYSTEM REQUIREMENT: To activate the Release Mode for sample removal, this vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This tray requires a compatible vacuum station and pump to activate release mode for sample removal, and must be handled under cleanroom conditions to prevent contamination. The packaging under dry inert nitrogen ensures zero contamination during transport, but the tray must be kept sealed until use.

  • Vacuum System Compatibility: The tray's release mode requires connection to a compatible Vacuum Station and Vacuum Pump system, which are sold separately.
  • Contamination Control: The tray is double-vacuum bag sealed under dry inert nitrogen gas to guarantee zero contamination, and must be opened only in a clean environment.
  • ESD Protection: Integrated anti-static matrices and conductive polymer backings provide dissipative pathways to eliminate electrostatic disruptions during handling.
  • Adhesive Performance: The high surface energy adhesive platform prevents micro-shifting during transport and eliminates residue upon non-destructive sample detachment.
  • Mesh Customization: Alternative mesh densities and colors can be specified in order remarks, but the default white 16 mesh is pre-installed.

This procedure describes the unpacking, sample loading, and vacuum release steps for the vacuum release tray. Ensure a cleanroom environment and compatible vacuum equipment are available before use.

Required Equipment: Vacuum Station, Vacuum Pump, ESD-safe work surface, Cleanroom gloves

  1. Unpack tray
    Open the double-vacuum bag in a cleanroom environment to avoid contamination.
  2. Place samples
    Position samples into the 10×10 grid compartments using clean tweezers or a vacuum wand.
  3. Connect vacuum system
    Attach the vacuum tray to the compatible Vacuum Station and Vacuum Pump system.
  4. Activate release mode
    Activate the release mode on the vacuum station to release the vacuum hold and allow sample removal.
  5. Remove samples
    Gently lift samples from the tray using appropriate tools, avoiding damage to the adhesive surface.

How does the high adhesion platform on the atomfair lid-type vacuum release tray ensure non-destructive sample detachment for delicate thin-film materials?

The tray's specially structured elastomer adhesive provides a reliable anchor hold while enabling micro-level non-destructive detachment, eliminating microscopic surface residue, adhesive transfer, or localized stress marks upon sample removal. This prevents thin-film peeling or device deformation, making it suitable for advanced materials such as 2D films, graphene, and quantum device fabrication.

What external vacuum system infrastructure is required to operate the atomfair lid-type vacuum release tray?

To activate the Release Mode for sample removal, the tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system. The tray itself has no integrated vacuum mechanism and relies on these external components to apply the necessary vacuum for controlled release.

What electrostatic discharge protection and contamination control measures are integrated into the atomfair lid-type vacuum release tray?

The tray incorporates integrated anti-static matrices and premium conductive polymer backings that provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions. Additionally, it is packaged double-vacuum bag sealed under a dry inert nitrogen gas atmosphere to guarantee zero contamination during transport.

This lid-type vacuum release tray with 100-grid high-adhesion platform provides precise sample isolation and non-destructive release for sensitive materials like quantum chips and 2D films, but requires dedicated vacuum station and pump for operation and demands explicit mesh configuration ordering.

Positive

  • Non-Destructive Sample Release: Specially structured elastomer provides reliable anchor hold while ensuring micro-level non-destructive sample detachment, preventing thin-film peeling or device deformation.
  • Comprehensive ESD Protection: Integrated anti-static matrices and conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions.

Trade-offs

  • Requires External Vacuum Infrastructure: To activate the Release Mode for sample removal, this tray must be used with a compatible Vacuum Station and Vacuum Pump system, adding infrastructure cost and setup requirements.
  • Mandatory Mesh Specification During Ordering: Default mesh is white 16 mesh; alternative densities (33, 76, 103, 137, 195) or yellow mesh must be explicitly stated in order remarks, requiring careful procurement specification.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Specification

ESD-safe full-black lid + conductive black tray + black insert 5pcs, Conductive full-black lid + conductive black tray + black insert 5pcs, ESD-safe clear lid + conductive black tray + clear insert 5pcs