Vacuum Release Tray 400 Grid Medium Adhesion ATOMFAIR®

$75.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research grade vacuum release tray with 400 grid 20×20 array, 1.52×1.44 mm compartments, medium adhesion, and ESD/conductive options; 5pcs. Order now.

SKU: AF-EI-A-PVRT-400M-CB00-PARENT
Category:
Brands:

PLUG-IN VACUUM RELEASE TRAY 400 GRID MEDIUM ADHESION

RESEARCH GRADE MATERIAL

Product Overview

The atomfair plug-in vacuum release tray is specifically engineered for critical research environments demanding high-purity, contamination-free, and cross-contamination-proof sample containment alongside meticulous microscopic particulate regulation. This specific configuration features a precision-molded 20×20 Grid Array matrix combined with an advanced Medium surface energy adhesive platform. It is custom-designed to prevent micro-shifting or structural dislodgement during rigorous transport, while simultaneously eliminating microscopic surface residue, adhesive transfer, or localized stress marks upon sample detachment. This non-destructive preservation platform is critical for advanced materials processing, quantum device fabrication, and delicate structural analysis across national frameworks and multi-disciplinary university core labs.

Technical Specifications

PARAMETER DETAILS
1. Core Specification Profile
Grid Configuration 400 Grid (20×20 Array, 1.52×1.44 mm Compartments)
Adhesion Level Medium Adhesion
2. Material Configurations & Ordering Codes
Model: AF-VRA-400M-CB ESD-safe full-black lid + conductive black tray + black insert
Model: AF-VRA-400M-CC Conductive full-black lid + conductive black tray + black insert
Model: AF-VRA-400M-CT ESD-safe clear lid + conductive black tray + clear insert
3. Mesh Selection Matrix
Default Mesh Specification White 16 Mesh
Available Mesh Densities 16 Mesh / 33 Mesh / 76 Mesh / 103 Mesh / 137 Mesh / 195 Mesh
Available Mesh Color Options Standard White Mesh / Yellow Mesh
Ordering Remark Guide If you need to purchase alternative mesh colors or densities, please explicitly state your specific requirements in the order remarks section during checkout.

Key Features & Advantages

  • Precise 20×20 Matrix Isolation: The orthogonal 400-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging.
  • Medium Residue Surface Energy: Specially structural elastomer allows reliable anchor hold while ensuring micro-level non-destructive sample detachment, preventing thin-film peeling or device deformation.
  • Comprehensive ESD Protection: Integrated anti-static matrices and premium conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions.
  • Vacuum & Structural Integrity: Engineered with premium chemical-resistant components to withstand continuous outgassing and multi-cycle depressurization without dimensional warping.

APPLICATION SCOPE: Highly recommended for quantum optics (qubit chips), materials science (2D films, graphene, nanomaterials), semiconductor R&D (MEMS, bare dies, compound wafers), and specialized biotechnology biosensor microfluidic arrays.
PACKAGING: Contains 5 × atomfair plug-in vacuum release tray (400 Grid / Medium Adhesion), 1 × cleanroom compliance certificate, and shock-absorbent shells. Double-vacuum bag sealed under dry inert nitrogen gas atmosphere to guarantee zero contamination during transport.
IMPORTANT ORDERING NOTICE: The default baseline configuration provided is white 16 mesh. If your project mandates alternative mesh counts (33, 76, 103, 137, or 195) or a yellow mesh configuration, please explicitly state your specific color and density requirements within the order remarks field during checkout confirmation.
SYSTEM REQUIREMENT: To activate the Release Mode for sample removal, this vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This tray requires a dedicated vacuum station and pump system for sample release. Storage must maintain a controlled atmosphere to prevent contamination, as the product is shipped under dry inert nitrogen.

  • System Requirement: The tray must be used with a compatible vacuum station and vacuum pump to activate the release mode for sample removal.
  • Atmospheric Sensitivity: The product is double-vacuum bag sealed under dry inert nitrogen to guarantee zero contamination during transport, indicating sensitivity to moisture and oxygen.
  • Adhesion Level Constraint: The medium adhesion platform is designed for non-destructive sample detachment but requires the vacuum release mechanism to prevent residue or stress marks.
  • ESD Protection Requirement: Integrated anti-static matrices and conductive polymer backings provide dissipative pathways, requiring proper grounding to eliminate electrostatic field disruptions.

This procedure describes the safe release of samples from the vacuum release tray. Ensure the vacuum station and pump are properly connected before activation.

Required Equipment: Vacuum Station, Vacuum Pump

  1. Prepare the System
    Inspect the vacuum station and tray for cleanliness and confirm all connections are secure.
  2. Position the Tray
    Place the tray securely onto the vacuum station platform to ensure proper seal.
  3. Connect the Vacuum Pump
    Connect the vacuum pump inlet to the station's vacuum port and verify the system is sealed.
  4. Activate Vacuum
    Turn on the vacuum pump and allow the system to reach the required operating pressure for release.
  5. Release the Sample
    Activate the release mode to disengage the adhesive grip, then carefully remove the sample using appropriate tools.

How does the Medium Adhesion surface energy of the 400-Grid plug-in vacuum release tray balance sample hold during transport against non-destructive detachment for fragile devices?

The medium adhesion structural elastomer is designed to provide reliable anchor hold preventing micro-shifting during rigorous transport while enabling micro-level non-destructive sample detachment without adhesive transfer or stress marks. This balance is critical for thin-film peeling prevention and device deformation avoidance in advanced materials processing and quantum device fabrication, as specified in the product's technical profile.

What external system infrastructure is required to operate the atomfair plug-in vacuum release tray and what are the optional mesh configuration constraints?

The tray requires a compatible Vacuum Station and Vacuum Pump system to activate Release Mode for sample removal, as stated in the system requirement notice. The default mesh is white 16 mesh, but alternative densities of 33, 76, 103, 137, and 195 mesh in standard white or yellow are available by specifying in the order remarks during checkout.

What storage and handling conditions are prescribed for the atomfair 400-Grid plug-in vacuum release tray to maintain its contamination-free integrity prior to use?

Each pack contains five trays double-vacuum sealed under dry inert nitrogen gas atmosphere with shock-absorbent shells and a cleanroom compliance certificate. To guarantee zero contamination, the trays should be stored in cleanroom conditions, preserving the conductive polymer backings and ESD-safe lid options until deployment.

The Atomfair plug-in vacuum release tray 400 grid medium adhesion provides a precision 20×20 grid array with medium adhesion for non-destructive sample handling and ESD protection, but requires external vacuum station and pump for release and mesh customization must be specified at order.

Positive

  • Precision 20×20 matrix isolation: The orthogonal 400-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging without cross-contamination.
  • Comprehensive ESD protection: Integrated anti-static matrices and conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions, critical for sensitive device handling.

Trade-offs

  • Requires external vacuum system: To activate Release Mode for sample removal, the tray must be used in conjunction with a compatible vacuum station and vacuum pump, adding infrastructure and cost.
  • Mesh customization must be specified at order: Alternative mesh densities (33, 76, 103, 137, 195) or yellow mesh require explicit notation in order remarks during checkout, which may introduce lead time or ordering complexity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Specification

ESD-safe full-black lid + conductive black tray + black insert 5pcs, Conductive full-black lid + conductive black tray + black insert 5pcs, ESD-safe clear lid + conductive black tray + clear insert 5pcs