160 L Dual-Flow Nitrogen Cabinet 1-60% RH ATOMFAIR®

$1,165.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

160 L dual-flow nitrogen cabinet with 1%-60% RH control, 450 × 450 × 1010 mm body, 3 shelves, and 15-50/1-5 L/min flow with automatic switching. Order now.

SKU: AF-EI-E-DFNC-STD0-160L
Category:
Brands:

Description

160L Dual-Flow Energy-Saving Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 160 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 450 × 450 × 1010 mm, inner dimensions of 405 × 420 × 840 mm and 3 adjustable shelves.

This dual-flow energy-saving nitrogen cabinet is designed for low-humidity storage tasks where fast recovery after door opening and reduced unnecessary gas consumption are both important. It supports moisture-sensitive materials that require controlled nitrogen-assisted drying while improving atmosphere recovery and lowering routine nitrogen demand.

Typical application areas include research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments where cabinet doors may be opened more frequently during routine work. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, dual-flow nitrogen management, automatic switching between large-flow and small-flow operation, tempered-glass viewing areas and perforated adjustable shelves for stable day-to-day cabinet performance.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-DFNC160
Product Family Dual-Flow Energy-Saving Nitrogen Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 160 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 450 × 450 × 1010 mm
Inner Dimensions (W × D × H) 405 × 420 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Automatic software-controlled nitrogen management
Large-Flow Meter Setting 15-50 L/min
Small-Flow Meter Setting 1-5 L/min
Switching Logic Automatic switching between large-flow and small-flow operation
Operating Characteristic Fast recovery after door opening with reduced unnecessary nitrogen use
Suitable Stored Materials Moisture-sensitive electronic parts, optical components and frequently accessed laboratory materials

Key Features and Advantages

  • Dual-flow nitrogen control with large-flow settings of 15-50 L/min and small-flow settings of 1-5 L/min.
  • Automatic switching between high-flow and low-flow operation without manual intervention.
  • Fast recovery after door opening helps restore the cabinet atmosphere while reducing unnecessary nitrogen consumption.
  • Sealed galvanized steel cabinet structure with tempered-glass viewing areas for controlled dry storage.
  • Perforated adjustable shelves support airflow circulation and flexible material arrangement.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, component staging rooms, optical storage spaces and inspection environments that require low-humidity nitrogen-assisted storage with rapid recovery after cabinet access.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable, level indoor surface and a reliable nitrogen gas supply with flow rates within the specified large-flow (15-50 L/min) and small-flow (1-5 L/min) ranges. Stored moisture-sensitive materials must be evenly distributed across shelves, and the cabinet door must remain sealed during normal operation to maintain the 1%-60% RH humidity control range.

  • Installation Requirement: Install the cabinet on a stable, level indoor surface and verify that the door seals properly before use.
  • Gas Supply Constraint: Ensure a stable nitrogen gas supply with flow rates not exceeding the large-flow meter setting of 15-50 L/min or small-flow setting of 1-5 L/min.
  • Load Distribution: Distribute stored items evenly across the three adjustable shelves to avoid overloading and maintain airflow circulation.
  • Operational Sealing: Keep the cabinet door closed during normal use to preserve the low-humidity atmosphere and minimize unnecessary nitrogen consumption.
  • Handling During Transport: Protect structural and sealing components during movement and use reinforced wooden-crate packaging for shipment protection.

The setup involves inspecting the delivered cabinet, installing it on a stable level surface, and connecting a nitrogen gas supply with appropriate flow rates. After verifying door sealing and even distribution of stored materials, the cabinet automatically manages humidity control through dual-flow switching.

  1. Inspect Cabinet
    Inspect the cabinet after delivery for any damage and verify that all components are present.
  2. Position Cabinet
    Position the cabinet on a stable, level indoor surface and ensure it is not tilted.
  3. Connect Gas Supply
    Connect a nitrogen gas supply to the cabinet inlet and set the large-flow meter to 15-50 L/min and small-flow meter to 1-5 L/min as needed.
  4. Distribute Materials
    Distribute moisture-sensitive materials evenly across the three adjustable shelves to maintain airflow.
  5. Close and Confirm
    Close the cabinet door securely and confirm that the humidity control system maintains the set range (1%-60% RH) through automatic switching.

How does the dual-flow nitrogen system balance fast humidity recovery with reduced nitrogen consumption in the 160 L cabinet?

The 160 L Dual-Flow Energy-Saving Nitrogen Cabinet uses automatic software-controlled switching between a large-flow meter setting of 15-50 L/min and a small-flow meter setting of 1-5 L/min. After a door opening, the high-flow stage accelerates atmosphere recovery, then the system automatically reverts to low-flow operation to minimize unnecessary nitrogen use. This logic is explicitly designed to improve recovery speed while lowering routine nitrogen demand, as stated in the product's operating characteristics.

Can the 160 L Dual-Flow Nitrogen Cabinet be used for storage of optical components and what humidity range must be maintained?

Yes, the cabinet is designed for moisture-sensitive materials including optical components, as listed in the suitable stored materials. The humidity control range is 1%-60% RH, and the cabinet maintains a low-humidity nitrogen-assisted environment with tempered-glass viewing doors and perforated adjustable shelves for airflow. The dual-flow system helps restore the cabinet atmosphere quickly after door openings, which is critical for frequently accessed optical storage spaces.

What are the gas supply and installation requirements for the 160 L Dual-Flow Nitrogen Cabinet?

The cabinet must be installed on a stable indoor surface with the door kept closed during normal use, and stored items should be evenly distributed across the three adjustable shelves. The handling notice emphasizes verifying stable gas-supply conditions before operation and confirming utility conditions such as power and gas connections before formal use. The cabinet uses automatic software-controlled nitrogen management with large-flow (15-50 L/min) and small-flow (1-5 L/min) meter settings, so a regulated nitrogen source with appropriate flow capacity is required.

The 160L Dual-Flow Energy-Saving Nitrogen Cabinet provides automatic switching between large-flow (15-50 L/min) and small-flow (1-5 L/min) operation, enabling rapid humidity recovery after door opening while minimizing nitrogen consumption, making it well-suited for frequently accessed low-humidity storage of moisture-sensitive parts in research and electronics laboratories.

Positive

  • Dual-flow nitrogen management with automatic switching: Automatically switches between large-flow (15-50 L/min) and small-flow (1-5 L/min) modes to achieve fast humidity recovery after door opening while reducing unnecessary nitrogen consumption, ideal for frequently accessed storage applications.
  • Sealed steel cabinet with tempered-glass doors: Constructed from 1.2 mm galvanized steel with magnetic sealing and 5 mm tempered-glass viewing doors, ensuring a robust, low-leakage enclosure for stable low-humidity atmosphere control.

Trade-offs

  • Dependence on external nitrogen supply: The cabinet requires a continuous, stable external nitrogen source to maintain low-humidity conditions; verifying gas supply and pressure is essential before operation, and nitrogen consumption must be budgeted for recurring use.
  • Standard cabinet lacks ESD or corrosion protection: The base model features a standard white galvanized steel body; for electrostatic-sensitive or corrosive environments, optional anti-static coating or stainless steel upgrades are required, adding cost and lead time.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).