HiPette Single-channel 30-300 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette requires periodic user calibration to maintain specified accuracy and precision. Sterilization must be performed via autoclaving to ensure repeatable performance and sample integrity.
- Calibration Requirement: User calibration must be conducted at test volumes of 30, 150, and 300 µL in accordance with ISO 8655-2 to verify systematic and random error tolerances.
- Sterilization Requirement: The pipette is fully autoclavable, requiring sterilization cycles that reach the necessary temperature and pressure without damaging the internal mechanism.
How does the accuracy of the HiPette 30-300 µL pipette vary across its volume range?
Systematic error increases from ±0.6% at 300 µL to ±2.5% at 30 µL, while random error increases from ±0.2% to ±0.7% over the same range. This means accuracy degrades significantly at lower volumes, which is a critical consideration for applications requiring precise microliter dispensing at the lower end of the range.
What pipette tip compatibility should I verify for the HiPette Single-channel 30-300 µL pipette?
The product description does not specify a particular tip brand or type; it directs users to confirm compatible tips before ordering. For routine use, standard 200–300 µL tips are typically suitable, but the manufacturer recommends verifying fit and sealing with the selected tip model to ensure accurate performance.
What are the sterilization and calibration requirements for the HiPette 30-300 µL pipette?
The pipette is fully autoclavable, allowing complete sterilization for contamination-sensitive workflows. Calibration follows ISO 8655-2 with user-adjustable values provided in the technical table; the manufacturer does not specify a fixed calibration interval, so it should be performed according to laboratory quality assurance protocols.
The HiPette single-channel 30-300 µL pipette offers fully autoclavable construction and ISO 8655-2 calibration data across three test volumes, but its 0.2 µL increment and higher relative error at 30 µL require careful volume selection for high-precision applications.
Positive
- Fully autoclavable sterilization: The entire pipette can be autoclaved without disassembly, enabling rapid decontamination and maintaining sterility for aseptic workflows.
- ISO 8655-2 calibration traceability: Systematic and random error values are provided at 300, 150, and 30 µL test volumes per ISO 8655-2, allowing users to verify performance at their operating points.
Trade-offs
- 0.2 µL increment limits fine adjustment: The 0.2 µL increment prevents setting intermediate volumes, which may be a constraint for methods requiring non-integer volumes within the 30-300 µL range.
- Higher relative error at low end: At 30 µL the systematic error is ±2.5% (±0.75 µL) and random error is ±0.7% (±0.21 µL), reducing accuracy for small-volume transfers compared to pipettes optimized for that range.