Single-Channel Manual Pipette 2-20 μL HiPette ATOMFAIR®

$88.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable single-channel manual pipette with 2-20 μL range, 0.02 μL increment, and ISO 8655-2 calibration reference. Order now.

SKU: AF-EI-L-HIPP-D020-SC00
Category: ,
Tags:
Brands:

Description

HiPette Single-channel 2-20 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette Single-channel 2-20 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 2-20 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 2-20 µL working range, 0.02 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 2-20 µL with 0.02 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-2-20-µL
Product Family HiPette
Channel count Single-channel
Volume range 2-20 µL
Increment 0.02 µL
Test volume(s) 20 / 10 / 2 µL
Systematic error At 20 µL: ±0.20 µL (±1.0%); at 10 µL: ±0.12 µL (±1.2%); at 2 µL: ±0.10 µL (±5.0%)
Random error At 20 µL: ±0.06 µL (±0.3%); at 10 µL: ±0.06 µL (±0.6%); at 2 µL: ±0.03 µL (±1.5%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The HiPette single-channel pipette requires periodic calibration per ISO 8655-2 to maintain systematic and random error specifications. Full autoclavability is supported, but the user must follow recommended sterilization cycles to prevent mechanical damage.

  • Calibration Requirement: Calibration must be performed at the specified test volumes of 20, 10, and 2 µL according to ISO 8655-2.
  • Sterilization Requirement: The pipette is fully autoclavable; users should adhere to the manufacturer's sterilization guidelines to avoid damage.

How does the accuracy of the HiPette 2-20 µL pipette at the 2 µL low end compare to its accuracy at 20 µL?

At the 2 µL low end, relative error is higher: systematic error is ±5.0% (±0.10 µL) and random error is ±1.5% (±0.03 µL). At 20 µL, relative error is lower: systematic error is ±1.0% (±0.20 µL) and random error is ±0.3% (±0.06 µL). This trade-off means users gain absolute precision at higher volumes but accept larger relative uncertainty at the minimum volume.

What tip types are compatible with the HiPette 2-20 µL pipette for accurate liquid handling?

The product description does not specify exact tip models or brands, but it states that compatible tips are required for accurate operation. Users should select tips designed for the 2-20 µL volume range and single-channel pipettes, such as standard 10 µL or 20 µL tips. For confirmed compatibility, contact the Atomfair technical sales team.

What sterilization method is recommended for the HiPette 2-20 µL pipette?

The HiPette 2-20 µL pipette is fully autoclavable, meaning it can be sterilized by autoclaving. No other sterilization methods are specified in the product description. Users should follow standard autoclave procedures for manual pipettes to maintain calibration and performance.

The HiPette Single-channel 2-20 µL pipette offers fully autoclavable construction and ISO 8655-2 traceable calibration data, but users should note the elevated systematic error of ±5.0% at the 2 µL test volume and its single-channel format, which limit precision at low volumes and throughput respectively.

Positive

  • Fully autoclavable for sterility assurance: The entire pipette can be autoclaved without disassembly, simplifying decontamination between experiments or when handling biohazardous materials.
  • ISO 8655-2 traceable calibration data: Systematic and random errors are provided at 20, 10, and 2 µL, enabling direct method validation and performance verification per international standards.

Trade-offs

  • Reduced accuracy at the lower end of the range: At 2 µL, the systematic error is ±5.0% (±0.10 µL), which may be unsuitable for applications requiring high precision at very low volumes.
  • Single-channel format limits throughput: The pipette handles one sample at a time, making it less efficient for large-scale parallel processing compared to multichannel pipettes.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).