StepMate Manual Repeating Pipette 0.5-50 mL ATOMFAIR®

$129.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable manual StepMate repeating pipette for 0.5 to 50 mL dispenser tips, serial aliquoting and plate reagent transfer. Order now.

SKU: AF-EI-L-STPM-REPT-NS00
Category: ,
Tags:
Brands:

Description

StepMate Repeating Pipette

Product Type: Repeating pipette
Research-grade liquid handling platform

Product Overview

StepMate Repeating Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.5 to 50 mL with compatible dispenser tips range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its multichannel format, 0.5 to 50 mL with compatible dispenser tips working range, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Multichannel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 0.5 to 50 mL with compatible dispenser tips.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-STEPMATE
Volume range 0.5 to 50 mL with compatible dispenser tips
Operation Manual repeating dispense
Application Serial dispensing, aliquoting, reagent addition and repeated liquid transfer
Liquid type Aqueous solutions, high-viscosity liquids and volatile liquids according to source application note
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The StepMate Repeating Pipette requires periodic calibration review using the specified systematic and random error values for each test volume. It is fully autoclavable for sterilization and must be used only with compatible dispenser tips and liquids within the 0.5 to 50 mL range.

  • Calibration Requirement: Verify calibration by comparing systematic and random errors against the listed test volumes.
  • Sterilization Procedure: Autoclave the pipette using standard laboratory autoclave cycles to ensure sterility.
  • Tip Compatibility: Use only compatible dispenser tips designed for this pipette model to ensure proper fit and accuracy.
  • Liquid Type Limitation: For high-viscosity or volatile liquids, refer to the source application note for appropriate handling techniques.

This pipette enables repeated parallel reagent transfer with precise volume control. Proper handling ensures accurate dispensing and maintains calibration integrity.

Required Equipment: Compatible dispenser tips

  1. Inspect pipette and tips
    Inspect the pipette and tips for cleanliness and any signs of damage before use.
  2. Attach tip
    Attach a compatible dispenser tip securely onto the pipette nozzle.
  3. Fill tip
    Draw liquid into the tip by slowly pulling the plunger upward until the desired volume is exceeded.
  4. Dispense aliquots
    Dispense the liquid in repeated aliquots by depressing the plunger to the stop for each individual volume.
  5. Eject tip
    Eject the used tip by pressing the tip ejector button after dispensing is complete.
  6. Sterilize if required
    Autoclave the pipette assembly according to standard laboratory procedures if sterilization is needed.

How does the StepMate Repeating Pipette's systematic error vary across its 0.5–50 mL working range when dispensing high-viscosity versus aqueous solutions?

The pipette supports both aqueous and high-viscosity liquids per its application note; systematic error values are listed by test volume for calibration review, enabling users to assess accuracy at specific volumes and liquid types.

What specific tip compatibility requirements must be met to ensure stable tip fit during repeated dispensing cycles with the StepMate Repeating Pipette?

The pipette requires compatible dispenser tips within its 0.5–50 mL range; users must confirm tip compatibility with Atomfair before ordering to ensure stable tip fit and accurate dispensing as stated in the product overview.

Can the StepMate Repeating Pipette be fully sterilized by autoclaving after use with volatile organic compounds without compromising its calibration?

Yes, it is fully autoclavable; when used with volatile liquids, users should follow the application note for safe handling and decontamination procedures.

The StepMate Repeating Pipette is a manual, fully autoclavable multichannel pipette with a 0.5–50 mL volume range, designed for repetitive liquid transfer in microplate and PCR workflows. It requires compatible dispenser tips and calibration verification per test volume to maintain specified accuracy.

Positive

  • Fully autoclavable for sterilization: The entire pipette can be autoclaved, enabling safe reuse and reducing contamination risk in microbiological and molecular biology workflows.
  • Multichannel configuration for microplate work: The multichannel format supports efficient loading of microplates, PCR plates, and ELISA assays, improving throughput for repetitive liquid transfers.

Trade-offs

  • Requires compatible dispenser tips: The pipette operates only with specific dispenser tips; users must confirm tip compatibility and availability before use.
  • Manual operation with calibration dependence: As a manual repeating pipette, consistent user technique is required, and calibration must be verified per test volume to maintain specified systematic and random error limits.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).