Description
dPette+ 8-channel 30-300 µL PipetteProduct Type: 8-channel electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The lower half of the pipette is autoclavable for sterilization, but the upper electronic assembly must not be autoclaved. Calibration must be verified against ISO 8655-2 at the specified test volumes to maintain accuracy.
- Sterilization constraint: Only the lower half of the pipette is autoclavable; the electronic upper assembly must be decontaminated by alternative methods.
- Calibration requirement: Systematic and random error tolerances are defined at 300, 150, and 30 µL per ISO 8655-2, requiring periodic recalibration to maintain specified performance.
How does the accuracy of the dPette+ 8-channel pipette vary across its 30–300 µL range?
The systematic error increases at lower volumes: at 300 µL it is ±0.60%, at 150 µL ±1.00%, and at 30 µL ±3.00%. Random error also increases: at 300 µL ±0.30%, at 150 µL ±0.50%, and at 30 µL ±1.00%. These values are from the technical specifications table.
What calibration standard does the dPette+ 8-channel pipette follow, and does it require special tips?
The pipette is calibrated per ISO 8655-2, as indicated in the technical table. The configuration support note states that compatible tips, calibration requirements, and sterilization needs must be confirmed before ordering. The pipette is designed for 8-channel microplate loading, PCR, and ELISA workflows, suggesting standard 200 µL or 300 µL tips, but the exact tip model is not specified in the source.
Is the dPette+ 8-channel pipette fully autoclavable for decontamination?
No, only the lower half of the pipette is autoclavable. The sterilization suitability is listed as 'Lower half autoclavable', meaning the upper electronic assembly must not be autoclaved. This is explicitly stated in the technical specifications.
The dPette+ 8-channel 30-300 µL Pipette is an electronic multichannel pipette offering parallel liquid handling for microplate and PCR workflows, with ISO 8655-2 calibration traceability and autoclavable lower half, but with constraints on full sterilization and user calibration requirements.
Positive
- 8-channel parallel processing: The 8-channel configuration enables simultaneous pipetting for microplate loading, PCR plate preparation, and ELISA workflows, increasing throughput and reproducibility in routine liquid handling.
- ISO 8655-2 calibration traceability: Systematic and random error values are provided per test volume with reference to ISO 8655-2, allowing users to verify performance and maintain calibration records for method compliance.
Trade-offs
- Limited sterilization compatibility: Only the lower half of the pipette is autoclavable; the upper assembly cannot be sterilized by autoclaving, requiring alternative disinfection procedures for full sterilization.
- User calibration required: Calibration is user-adjustable via ISO 8655-2 reference, necessitating access to calibration tools and expertise to maintain specified accuracy over time.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).