dPette+ 8-channel 20-200 µL PipetteProduct Type: 8-channel electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires that only its lower half be autoclaved for sterilization. Calibration must adhere to ISO 8655-2 limits for systematic and random error at the specified test volumes.
- Sterilization constraint: The lower half of the pipette may be autoclaved; the upper electronic assembly must not be subjected to steam sterilization.
- Calibration constraint: Calibration must be performed at test volumes 200 µL, 100 µL, and 20 µL with acceptance criteria per systematic and random error values listed.
- Tip compatibility constraint: The pipette requires compatible 8-channel tips for the 20-200 µL volume range to ensure proper fit and accuracy.
How does the systematic error of the dPette+ 8-channel pipette vary across the 20-200 µL volume range?
The systematic error increases proportionally at lower volumes. At 200 µL it is ±1.20 µL (±0.60%), at 100 µL it is ±1.00 µL (±1.00%), and at 20 µL it is ±0.80 µL (±4.00%). The random error at 20 µL is ±0.20 µL (±1.00%). These values are specified per the ISO 8655-2 calibration reference.
Can the dPette+ 8-channel pipette be fully sterilized, or only partially?
Only the lower half of the pipette is autoclavable; the upper electronic assembly is not. This is a key constraint for applications requiring complete sterilization of the entire instrument, such as certain aseptic cell culture or PCR workflows.
What calibration standard is used for the dPette+ 8-channel pipette, and does it support user calibration?
The pipette is calibrated according to ISO 8655-2 and includes a user calibration reference. Systematic and random errors are provided at test volumes of 200, 100, and 20 µL for routine performance verification.
The dPette+ 8-channel 20-200 µL pipette offers parallel liquid handling capability with a 1 µL increment, but its lower-half autoclavability limits sterilization coverage and the systematic error at 20 µL reaches ±4.00%, which may constrain low-volume precision workflows.
Positive
- 8-channel parallel pipetting: 8-channel configuration enables simultaneous microplate loading, PCR plate preparation, and ELISA workflows, increasing throughput for repeated parallel reagent transfer.
- Low random error at high volume: Random error at 200 µL is ±0.60 µL (±0.30%), providing repeatable performance for routine liquid handling at the upper end of the volume range.
Trade-offs
- Limited autoclavability: Only the lower half is autoclavable; the upper electronic assembly cannot be steam-sterilized, requiring careful disassembly and alternative decontamination methods for full sterilization.
- Higher systematic error at 20 µL: Systematic error at the 20 µL test volume is ±0.80 µL (±4.00%), which may compromise accuracy for low-volume applications compared to the ±0.60% error at 200 µL.