Description
dPette Single-channel 0.5-10 µL PipetteProduct Type: Electronic pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The dPette single-channel pipette requires routine calibration per ISO 8655-2 and supports autoclaving of its lower half. Proper tip selection and volume verification are necessary to maintain specified systematic and random error limits.
- Sterilization Constraint: Only the lower half of the pipette is autoclavable; do not autoclave the upper assembly.
- Calibration Requirement: Calibrate the pipette using the three test volumes (10, 5, 1 µL) per ISO 8655-2 to maintain accuracy.
- Tip Compatibility: Use only compatible pipette tips that fit the 0.5-10 µL range to avoid leakage and inaccuracy.
How does the dPette 0.5-10 µL pipette's accuracy and precision vary across its volume range, and what are the implications for low-volume assays?
The systematic error at 10 µL is ±1.00%, at 5 µL ±2.00%, and at 1 µL ±5.00%. Random error at 10 µL is ±0.50%, at 5 µL ±2.00%, and at 1 µL ±3.00%. This significant degradation in both accuracy and precision at the lowest end of the range means that for applications such as PCR setup or serial dilutions requiring volumes near 1 µL, the pipette may introduce higher relative error, requiring careful method validation or use of a lower-volume pipette.
What are the critical compatibility and sterilization constraints for the dPette 0.5-10 µL pipette in a BSL-2 or PCR laboratory?
The pipette's lower half is autoclavable, but the upper half is not, so full sterilization of the entire pipette is not possible. Users must confirm compatible tips before ordering, as the 0.5-10 µL range requires specific tip types. The pipette also requires calibration per ISO 8655-2, which may need to be repeated after autoclaving to maintain specification.
What calibration and maintenance procedures are required for the dPette 0.5-10 µL pipette to ensure reliable performance?
The pipette is calibrated according to ISO 8655-2, with test volumes at 10, 5, and 1 µL. For routine maintenance, the lower half can be autoclaved, but the user should confirm compatible tips, calibration requirements, and sterilization needs before ordering. Regular calibration verification is recommended, especially after autoclaving or when switching between different liquids, to ensure systematic and random errors remain within specifications.
The dPette Single-channel 0.5-10 µL Pipette offers a fine 0.01 µL increment and partial autoclavability for contamination control, but accuracy degrades at the lower end of the range (1 µL ±5% systematic error) and full sterilization is limited to the lower half.
Positive
- Lower half autoclavable for contamination control: The lower half of the pipette can be autoclaved, enabling sterilization of the tip contact area to reduce cross-contamination risk in aseptic workflows.
- Fine 0.01 µL increment for precise volume selection: The 0.01 µL increment allows fine adjustment of dispensed volumes, supporting accurate microvolumetric transfers within the 0.5-10 µL range.
Trade-offs
- Large systematic error at 1 µL test volume: At 1 µL, the systematic error is ±5.00%, which may limit accuracy for low-volume applications requiring high precision.
- Only lower half autoclavable, not full unit: The upper half of the pipette is not autoclavable, requiring alternative sterilization methods for the entire device or careful handling to maintain sterility.