Description
Mini Pipette Single-channel 60 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This fixed-volume manual pipette is not suitable for high-temperature sterilization, requiring alternative low-temperature or chemical disinfection methods. Calibration must be performed per ISO 8655-2 to maintain stated accuracy and precision at the 60 µL test volume.
- Sterilization constraint: Do not autoclave or expose this pipette to high-temperature sterilization as it will damage the internal mechanism and compromise volume accuracy.
- Calibration requirement: Verify systematic error (±1.50 µL) and random error (±1.00 µL) at 60 µL using ISO 8655-2 gravimetric methods before first use and after any mechanical or thermal stress.
What are the systematic and random error specifications for the Atomfair 60 µL fixed-volume pipette, and how are they calibrated?
The systematic error at 60 µL is ±1.50 µL (±0.3%) and the random error is ±1.00 µL (±0.2%). The calibration reference follows ISO 8655-2, as indicated in the technical table. These specifications ensure traceable accuracy for routine liquid transfer and assay setup.
What tip compatibility requirements exist for the Atomfair Mini Pipette Single-channel 60 µL Pipette?
The pipette requires compatible tips that match the 60 µL fixed volume and single-channel format. The manufacturer advises confirming compatible tips before ordering. No specific tip brand or model is specified in the product documentation.
Can the Atomfair Mini Pipette Single-channel 60 µL Pipette be sterilized by autoclaving?
No, the pipette is not suitable for high-temperature sterilization. The product description does not list alternative sterilization methods, so users should contact the manufacturer or consult laboratory protocols for non-thermal sterilization options before use.
The Atomfair Mini Pipette Single-channel 60 µL is a fixed-volume manual pipette providing traceable accuracy and precision per ISO 8655-2, but it lacks autoclavability and its fixed volume limits workflow flexibility.
Positive
- ISO 8655-2 Calibration Reference: Systematic and random error values are specified per test volume (60 µL: ±1.50 µL systematic, ±1.00 µL random), enabling direct calibration traceability and routine performance review.
- Single-Channel Fixed-Volume Precision: The single-channel format and exact 60 µL fixed volume ensure reproducible liquid transfer for single-tube applications such as PCR setup and serial dilution without volume adjustment variability.
Trade-offs
- Not High-Temperature Sterilizable: The pipette is explicitly not suitable for high-temperature sterilization, requiring alternative chemical disinfection or limited aseptic use in workflows that demand autoclave compatibility.
- Fixed-Volume Operating Constraint: As a fixed-volume pipette, it cannot adjust to different target volumes; any method change requiring a different dispensing amount necessitates an entirely separate pipette or additional equipment.