Description
Mini TopPette Single-channel 300 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This fixed-volume pipette is not suitable for high-temperature sterilization and requires user calibration per ISO 8655-2. It must be used with compatible tips and within its specified error tolerances to ensure accurate liquid handling.
- Sterilization Restriction: This pipette is not suitable for high-temperature sterilization and must be cleaned using alternative methods approved by the manufacturer.
- Calibration Requirement: User calibration must be performed according to ISO 8655-2 reference to maintain accuracy specifications.
- Fixed Volume Constraint: The pipette has a fixed volume of 300 µL and cannot be adjusted to other volumes.
- Accuracy Tolerances: Systematic and random errors at 300 µL are ±1.00 µL and ±0.50 µL respectively, requiring regular verification against these limits.
How do the systematic error (±0.4%) and random error (±0.2%) of the Mini TopPette 300 µL pipette at the 300 µL test volume reflect its accuracy vs. precision trade-off, and what does this mean for high-precision applications like qPCR?
At the 300 µL test volume, the Mini TopPette pipette has a systematic error of ±1.00 µL (±0.4%) and a random error of ±0.50 µL (±0.2%). This indicates that the pipette is more precise than accurate, with random error being half the systematic error. For high-precision workflows such as qPCR, the low random error ensures consistent replicate measurements, while the systematic error can be corrected through calibration.
What calibration standard does the Mini TopPette 300 µL pipette follow, and how does this affect its integration into laboratories that require ISO 8655 compliance?
The Mini TopPette 300 µL pipette is calibrated per ISO 8655-2, a standard for piston-operated volumetric apparatus. Integration into an ISO 8655-compliant laboratory requires that the pipette's user calibration reference be followed for routine performance checks and that calibration records be maintained.
What are the sterilization constraints for the Mini TopPette 300 µL pipette, and what alternative decontamination methods are recommended based on the manufacturer's specifications?
According to the technical specifications, the Mini TopPette 300 µL pipette is not suitable for high-temperature sterilization. The product description does not specify alternative decontamination methods, so users should directly contact Atomfair technical support for recommended cleaning and sterilization procedures that do not compromise the pipette's performance.
The Mini TopPette 300 µL fixed-volume pipette provides repeatable single-channel liquid transfer with ISO 8655-2 calibration traceability, but its lack of autoclave compatibility and fixed volume limit flexibility for varied protocols.
Positive
- Fixed volume eliminates selection error: The 300 µL fixed increment ensures consistent volume delivery without adjustment variability, reducing operator-dependent errors in routine transfers.
- ISO 8655-2 calibration reference: Calibration traceable to ISO 8655-2 provides documented accuracy and precision data for method validation and quality control compliance.
Trade-offs
- Not autoclavable: This pipette is not suitable for high-temperature sterilization, requiring alternative chemical or UV decontamination methods that may limit use in aseptic workflows.
- Fixed volume only: The single 300 µL fixed volume offers no flexibility for different liquid volumes, necessitating additional pipettes for multi-volume protocols.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).