Description
Mini TopPette Single-channel 100 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This fixed-volume manual pipette requires user calibration per ISO 8655-2 to maintain accuracy. The device is not suitable for high-temperature sterilization and requires compatible tips for proper operation.
- Calibration Requirement: Calibrate the pipette at the specified test volume of 100 µL per ISO 8655-2 to achieve the systematic error of ±0.50 µL and random error of ±0.30 µL.
- Sterilization Restriction: Do not subject the pipette to high-temperature sterilization as the mechanism may be damaged; use low-temperature or chemical sterilization methods instead.
- Tip Compatibility: Confirm that the selected pipette tips are compatible with the fixed-volume 100 µL pipette to ensure a secure seal and accurate liquid handling.
How do the systematic and random error specifications of the Mini TopPette 100 µL fixed-volume pipette affect its suitability for high-accuracy applications like PCR and serial dilution?
At the 100 µL test volume, the pipette exhibits a systematic error of ±0.50 µL (±0.5%) and a random error of ±0.30 µL (±0.3%), each meeting ISO 8655-2 standards. These specifications make it suitable for routine liquid handling tasks such as PCR setup, serial dilution, and reagent addition where repeatability is required. The fixed-volume design ensures consistent delivery at the single 100 µL point, eliminating adjustment variability.
What sterilization or decontamination methods are compatible with the Mini TopPette 100 µL pipette since it is not suitable for high-temperature autoclaving?
The Mini TopPette 100 µL pipette is explicitly not suitable for high-temperature sterilization. For decontamination, chemical methods such as wiping with 70% ethanol or 10% bleach may be used, but users should verify material compatibility. For PCR or RNA work, using filtered tips and regular surface decontamination is recommended to prevent cross-contamination. Contact Atomfair for validated decontamination protocols.
What calibration requirements and procedures are needed for the Mini TopPette 100 µL pipette to maintain ISO 8655-2 compliance?
The pipette is calibrated per ISO 8655-2 with systematic error (±0.50 µL) and random error (±0.30 µL) specified at the 100 µL test volume. User calibration verification should be performed periodically based on usage frequency and application criticality. Because it is a fixed-volume pipette, calibration only requires checking the single 100 µL volume, simplifying the process. For detailed calibration planning, contact Atomfair technical sales.
The Mini TopPette 100 µL fixed-volume pipette offers reliable single-channel liquid handling with ISO 8655-2 traceable calibration, but its lack of autoclavability and fixed volume limit its application to dedicated 100 µL workflows.
Positive
- Fixed-volume precision: Fixed 100 µL volume eliminates adjustment variability, with systematic error of ±0.50 µL and random error of ±0.30 µL at the test volume, ensuring consistent delivery for routine liquid transfer.
- ISO 8655-2 calibration traceability: Technical specifications reference user calibration per ISO 8655-2, supporting method validation and compliance in research and quality-control laboratories.
Trade-offs
- No high-temperature sterilization: The pipette is explicitly not suitable for high-temperature sterilization, limiting decontamination options and requiring alternative sterilization methods or careful handling to avoid cross-contamination.
- Fixed volume restricts flexibility: The fixed 100 µL increment precludes volume adjustment, confining the pipette to applications requiring exactly that volume and necessitating additional pipettes for other volumes.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).