TopPette 8-Channel 50-200 μL Manual Pipette ATOMFAIR®

$160.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

8-channel TopPette manual pipette for 50-200 μL transfer, 1 μL increments, lower-half autoclaving and ISO 8655-2 calibration review. Order now.

SKU: AF-EI-L-TOPP-K200-08CH
Category: ,
Tags:
Brands:

Description

TopPette 8-channel 50-200uL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette 8-channel 50-200 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 50-200uL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 50-200uL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 50-200uL with 1 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-8CHANNEL-50-200-µL
Product Family TopPette
Channel count 8-channel
Volume range 50-200uL
Increment 1 µL
Test volume(s) 200 / 100 / 50 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The pipette requires calibration per ISO 8655-2 at test volumes 200, 100, and 50 µL to maintain specified systematic and random error limits. Only the lower half is autoclavable; correct reassembly is required after sterilization to prevent contamination.

  • Calibration Compliance: Calibrate the pipette at the specified test volumes (200, 100, 50 µL) according to ISO 8655-2 to ensure accuracy.
  • Sterilization Procedure: Autoclave only the lower half of the pipette at the recommended cycle and reassemble correctly after sterilization.
  • Tip Compatibility: Select tips validated for 50-200 µL range and 8-channel pipettes to achieve proper seal and volume delivery.
  • Volume Range Adherence: Operate within the 50-200 µL working range and use the 1 µL increment for fine adjustments only within this range.

What are the systematic error values for the TopPette 8-channel 50-200 µL pipette at the specified test volumes?

The product description specifies that systematic error values are retained by test volume in the technical table, but exact numerical figures are not reprinted in the text. The test volumes are 200 µL, 100 µL, and 50 µL. For precise systematic error data, consult the technical table supplied with the pipette, which is calibrated according to ISO 8655-2.

Can the TopPette 8-channel pipette be used for PCR plate preparation?

Yes, the product description explicitly lists PCR plate preparation as a key application, along with microplate loading and ELISA workflows. The 8-channel format and 50-200 µL range are designed for efficient parallel reagent transfer in 96-well plates commonly used in PCR.

Is the TopPette 8-channel pipette fully autoclavable?

No, the pipette is not fully autoclavable. The specifications state that only the lower half is autoclavable where indicated. Users should follow the provided sterilization instructions to avoid damaging the upper assembly.

The TopPette 8-channel 50-200 µL manual pipette delivers reproducible parallel liquid handling for microplate workflows, with autoclavable lower half for contamination control and ISO 8655-2 traceable calibration data, though tip compatibility and partial sterilization coverage require careful lab protocol integration.

Positive

  • Multichannel parallel dispensing efficiency: Eight-channel format enables simultaneous microliter transfers for microplate loading, PCR plate preparation, and ELISA workflows, reducing operator time and improving well-to-well consistency in high-throughput setups.
  • Autoclavable lower half for sterility: The lower half is autoclavable, allowing periodic decontamination between experiments without requiring full pipette disassembly, supporting aseptic technique in teaching and quality-control laboratories.

Trade-offs

  • Partial autoclavability only: Only the lower half is autoclavable; the upper assembly must not be autoclaved, requiring users to follow specific sterilization protocols to avoid damaging non-autoclavable components.
  • Mandatory tip compatibility verification: Accurate volume delivery and tip seal integrity depend on using compatible tips, which must be confirmed prior to use to prevent leakage, imprecision, or calibration drift during routine operation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).