Mini TopPette 50 μL Fixed-Volume Manual Pipette ATOMFAIR®

$4.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fixed-volume Mini TopPette manual pipette for 50 μL transfers, with ±0.25 μL systematic and ±0.15 μL random error per ISO 8655-2. Order now.

SKU: AF-EI-L-MTOP-K050-SC00
Category: ,
Tags:
Brands:

Description

Mini TopPette Single-channel 50 µL Pipette

Product Type: Fixed-volume mini pipette
Research-grade liquid handling platform

Product Overview

Mini TopPette Single-channel 50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 50 µL working range, Fixed volume increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 50 µL with Fixed volume increment.
  • Sterilization suitability: Not suitable for high-temperature sterilization.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MINI-TOPPETTE-50-µL
Product Family Mini TopPette
Channel count Single-channel
Volume range 50 µL
Increment Fixed volume
Test volume(s) 50 µL
Systematic error At 50 µL: ±0.25 µL (±0.5%)
Random error At 50 µL: ±0.15 µL (±0.3%)
Sterilization suitability Not suitable for high-temperature sterilization
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Fixed-volume pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This fixed-volume pipette is not suitable for high-temperature sterilization and requires periodic calibration per ISO 8655-2. Compatible tips must be confirmed prior to use to ensure proper fit and accuracy.

  • Sterilization Limitation: This pipette is not suitable for high-temperature sterilization methods.
  • Calibration Reference: Calibration must be performed according to ISO 8655-2 user calibration reference.
  • Tip Compatibility: Compatible tips must be confirmed to ensure stable tip fit and accurate liquid handling.

What are the accuracy and precision specifications for the Mini TopPette 50 µL fixed-volume pipette at its single test volume?

At the 50 µL test volume, the systematic error is ±0.25 µL (±0.5%) and the random error is ±0.15 µL (±0.3%), as listed in the technical specifications. These values are calibrated per ISO 8655-2, providing a performance baseline for method setup and routine quality control.

Can the Mini TopPette 50 µL pipette be used for PCR or qPCR setup given its fixed-volume design and sterilization limitations?

Yes, the pipette is suitable for PCR and qPCR setup, as the product overview explicitly includes these workflows. However, because it is not suitable for high-temperature sterilization, decontamination must rely on alternative methods such as chemical disinfection or UV irradiation, rather than autoclaving.

What are the sterilization requirements for the Mini TopPette 50 µL pipette, and how do they affect routine laboratory workflow?

The pipette is explicitly marked as not suitable for high-temperature sterilization. This means it cannot be autoclaved, so laboratories must use alternative sterilization or decontamination protocols (e.g., 70% ethanol wipes, chemical disinfectants) between uses. This limitation should be factored into workflow planning, especially for applications requiring sterile handling.

The Mini TopPette Single-channel 50 µL Pipette is a fixed-volume manual pipette offering precise liquid handling with low systematic error (±0.5%) and random error (±0.3%) at 50 µL, but it is not autoclavable and lacks volume adjustability, limiting its use to dedicated 50 µL applications that do not require high-temperature sterilization.

Positive

  • Low systematic and random error: At 50 µL, systematic error is ±0.25 µL (±0.5%) and random error is ±0.15 µL (±0.3%), ensuring reproducible liquid transfer for routine assays and PCR setup per ISO 8655-2 calibration reference.
  • Single-channel fixed-volume design: The single-channel format and fixed 50 µL volume simplify operation for dedicated tasks such as sample preparation, serial dilution, and reagent addition, reducing the risk of volume selection errors.

Trade-offs

  • Not suitable for high-temperature sterilization: The pipette is explicitly marked as not suitable for high-temperature sterilization, requiring alternative decontamination methods (e.g., chemical disinfection) that may affect compatibility with certain protocols.
  • Fixed volume increment limits flexibility: With a fixed volume of 50 µL, the pipette cannot be adjusted for other volumes, which restricts its use to applications that consistently require exactly 50 µL and may necessitate additional pipettes for variable-volume workflows.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).