12-Channel Manual Pipette 30-300 μL TopPette ATOMFAIR®

$168.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

12-channel TopPette manual pipette with 30-300 μL range, 5 μL increments, ISO 8655-2 calibration reference and lower-half autoclaving. Order now.

SKU: AF-EI-L-TOPP-J300-12CH
Category: ,
Tags:
Brands:

Description

TopPette 12-channel 30-300 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette 12-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 30-300 µL working range, 5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 30-300 µL with 5 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-12CHANNEL-30-300-µL
Product Family TopPette
Channel count 12-channel
Volume range 30-300 µL
Increment 5 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic gravimetric calibration per ISO 8655‑2 to maintain specified accuracy across test volumes. The lower half is autoclavable for sterilization; tip compatibility must be verified before use.

  • Sterilization Constraint: The lower half of this pipette is autoclavable when indicated; follow standard autoclave procedures for laboratory instruments.
  • Calibration Requirement: Calibration must be performed according to ISO 8655‑2 using gravimetric methods at each specified test volume (300 µL / 150 µL / 30 µL).
  • Tip Compatibility: Use only tips certified for multichannel pipettes within the working range of 30–300 µL to ensure proper sealing and accuracy.
  • Volume Setting Constraint: Set volume only within the specified range of 30–300 µL using the incremental adjustment of 5 µL per click.

Required Equipment:

What is the volume increment of the TopPette 12-channel pipette and how does it affect volume selection?

The TopPette 12-channel 30-300 µL pipette has a 5 µL increment, enabling fine volume adjustment within the 30–300 µL range. This increment supports precise microplate loading, PCR plate preparation, and ELISA workflows where repeatable, sub-microliter control is not required but consistent parallel transfer is essential.

Can the TopPette 12-channel pipette be used for 96-well plate filling?

Yes, the 12-channel configuration is specifically designed for microplate loading, PCR plate preparation, and ELISA workflows, making it suitable for 96-well plate filling. Users must confirm compatible tips before ordering, as tip fit is critical for repeatable parallel reagent transfer.

Is the TopPette 12-channel pipette fully autoclavable?

No, only the lower half of the pipette is autoclavable where indicated. Full sterilization of the entire pipette is not supported; users should refer to the technical specifications to confirm sterilization suitability for their workflow.

The TopPette 12-channel 30-300 µL pipette is a manual multichannel pipette designed for high-throughput microplate and PCR plate workflows, with partial autoclavability and ISO 8655-2 calibration. Its operational constraints include limited sterilization coverage and requirement for pre-order compatibility checks.

Positive

  • 12-channel parallel pipetting for microplate workflows: The 12-channel configuration enables simultaneous liquid transfer in microplate loading, PCR plate preparation, and ELISA assays, improving throughput and reproducibility in parallel reagent handling.
  • Autoclavable lower half for sterilization: The lower half of the pipette is autoclavable, reducing cross-contamination risk between samples when sterilization is required for routine laboratory use.

Trade-offs

  • Partial autoclavability only: Only the lower half is autoclavable; the upper assembly must be cleaned separately, adding handling steps and limiting full-sterilization capability.
  • Pre-order tip and calibration validation required: The product requires users to confirm compatible tips, calibration requirements, and sterilization needs before ordering, as indicated in the configuration support section, adding pre-purchase planning overhead.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).